Photon-counting detector CT for prediction of valve dysfunction after transcatheter aortic valve implantation: Comparison with echocardiography.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hyska Sardi, Osoria-Velasquez José, Hagar Muhammad Taha, McCraw Gavin W, Vecsey-Nagy Milán, Ricke Jens, Mueller Nicola, Bäuerle Tobias, Maurovich-Horvat Pál, Laux Gerald S, Hell Michaela, Emrich Tilman, Varga-Szemes Akos, Halfmann Moritz C
Аннотация
BACKGROUND: Noninvasive evaluation of suspected prosthetic valve dysfunction after transcatheter aortic valve implantation (TAVI) remains challenging because both anatomic and hemodynamic information are required for a conclusive diagnosis.
PURPOSE: To evaluate the diagnostic accuracy of hemodynamic parameters derived from time-resolved photon-counting detector (PCD)-CT for functional TAVI-assessment.
METHODS: In this retrospective single-center study, consecutive post-TAVI PCD-CT examinations acquired between January 2023 and December 2025 were screened. After CT-based exclusion of cases with severe mitral regurgitation, systolic prosthetic valve orifice area was measured to calculate mean and maximum transvalvular pressure gradients (Pmean/Pmax) from time-resolved left ventricular volumetry. Spearman correlation (ρ) and paired comparisons were performed with transthoracic echocardiography (TTE) as reference standard. Diagnostic performance of CT-derived Pmean for identifying potential valve dysfunction was assessed.
RESULTS: Seventy-one post-TAVI PCD-CT scans of 63 patients (median age, 77.0 [73.5-83.0] years; 37 women) were included. CT-derived parameters showed strong correlations and high agreement with their echocardiographic counterparts (orifice area: ρ = 0.73; Pmean: ρ = 0.85; Pmax: ρ = 0.85; p < 0.001). There was no bias for orifice area or Pmean, whereas CT-derived Pmax was higher than TTE-based Pmax (median difference, 4.4 mmHg; p < 0.001). CT-derived Pmean showed high diagnostic performance for detection of potential valve dysfunction, with an area under the curve of 0.94, sensitivity/specificity of 88.9%/88.6%, accuracy of 88.7% and Youden index-derived optimal cutoff of 20.4 mmHg.
CONCLUSION: Time-resolved cardiac PCD-CT for post-TAVI imaging enables robust derivation of mean transvalvular pressure gradients that correlate strongly with echocardiography, show excellent diagnostic accuracy for screening of valve dysfunction and may expand the diagnostic value of cardiac CT toward functional assessment.
PURPOSE: To evaluate the diagnostic accuracy of hemodynamic parameters derived from time-resolved photon-counting detector (PCD)-CT for functional TAVI-assessment.
METHODS: In this retrospective single-center study, consecutive post-TAVI PCD-CT examinations acquired between January 2023 and December 2025 were screened. After CT-based exclusion of cases with severe mitral regurgitation, systolic prosthetic valve orifice area was measured to calculate mean and maximum transvalvular pressure gradients (Pmean/Pmax) from time-resolved left ventricular volumetry. Spearman correlation (ρ) and paired comparisons were performed with transthoracic echocardiography (TTE) as reference standard. Diagnostic performance of CT-derived Pmean for identifying potential valve dysfunction was assessed.
RESULTS: Seventy-one post-TAVI PCD-CT scans of 63 patients (median age, 77.0 [73.5-83.0] years; 37 women) were included. CT-derived parameters showed strong correlations and high agreement with their echocardiographic counterparts (orifice area: ρ = 0.73; Pmean: ρ = 0.85; Pmax: ρ = 0.85; p < 0.001). There was no bias for orifice area or Pmean, whereas CT-derived Pmax was higher than TTE-based Pmax (median difference, 4.4 mmHg; p < 0.001). CT-derived Pmean showed high diagnostic performance for detection of potential valve dysfunction, with an area under the curve of 0.94, sensitivity/specificity of 88.9%/88.6%, accuracy of 88.7% and Youden index-derived optimal cutoff of 20.4 mmHg.
CONCLUSION: Time-resolved cardiac PCD-CT for post-TAVI imaging enables robust derivation of mean transvalvular pressure gradients that correlate strongly with echocardiography, show excellent diagnostic accuracy for screening of valve dysfunction and may expand the diagnostic value of cardiac CT toward functional assessment.