m+Medelevator.RU
← Поиск публикаций
World journal of surgical oncology · 2019

Radiolocalization of atypical lesions for intraoperative identification: technical factors, localization quality, success rates, patient safety, and spectrum of applications.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Young Jason R, Wallig Andi E, Fischer Nichole L, Swanson Tiffinee N, Truty Mark J, Shen K Robert, McMenomy Brendan P

Аннотация

BACKGROUND: To retrospectively analyze perilesional technetium Tc-99m MAA injection for intraoperative localization of atypical soft-tissue and bone lesions within a single tertiary referral center in order to determine technique, safety, and clinical utility of these procedures.

METHODS: An IRB compliant, retrospective electronic chart review (2010-2017) exploring surgical excision of atypical (non-pulmonary, non-breast, non-sentinel node) lesions guided by Tc-99m MAA perilesional injection. Patient demographics, lesion location, lesion size, radiotracer injection technique, radiotracer injection complications, scintigraphy technique, scintigraphic quality, intraoperative time, lesion identification in surgery, and pathological diagnoses were recorded.

RESULTS: Twenty-two atypical radiolocalization exams were identified. Lesion sites included rib (7), lymph node (4), abdominal wall (3), mesenteric (3), gallbladder fossa (1), retroperitoneum (1), parietal pleura (1), anterior mediastinum (1), and iliac bone (1). Average lesion size was 14 mm (range 5-23 mm). Eighteen (82%) radiotracer injections used computed tomography guidance and 4 (18%) used ultrasound guidance. The mean activity of Tc-99m MAA administered was 11.8 MBq (0.32 mCi). A 22-gauge needle was most often used for perilesional injection. No injection complications were reported. The lesions were identified with a hand-held gamma probe during surgery in 100% of cases. Of the samples sent to pathology, 100% were identified and given a diagnosis.

CONCLUSION: Radiolocalization of atypical lesions may be a valuable technique, guiding minimally invasive surgical removal of lesions that would otherwise be difficult to identify intraoperatively such as non-palpable rib, central mesenteric nodal, and abdominal wall lesions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты