MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpurol.2025.05.004

Медицинская библиотека · Journal of pediatric urology · 2025

Objective assessment of penile curvature in hypospadias: A narrative review.

Babu Ramesh, Chandrasekharam Vvs, Abbas Tariq O

СтатьяСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Hypospadias-associated ventral curvature (VC) exerts a critical influence on surgical decision-making and repair outcomes. Despite the clinical significance of VC, assessment is frequently performed by unaided visual inspection (UVI) which is prone to error. Alternative objective measurement techniques have therefore been proposed, including goniometry, smartphone applications, and artificial intelligence (AI)-based tools.

OBJECTIVE

This review aims to evaluate the various techniques available for VC measurement in hypospadias surgery, focusing on their accuracy, reliability, and clinical utility.

METHODS

A comprehensive literature search was conducted using PubMed, MEDLINE, and the Cochrane Database, covering publications from 1994 to 2024. Included studies assessed VC measurement techniques, including UVI, standard goniometry, smartphone-based goniometry, and AI-based tools. Risk of bias was determined using the Robvis tool.

RESULTS

Of 501 studies identified, 13 met the inclusion criteria. Findings revealed that UVI was associated with significant inaccuracy, leading to misclassification of VC severity and potential errors in surgical planning. Standard goniometry, while objective, was cumbersome in pediatric patients due to parallax errors and anatomical constraints. Smartphone-based goniometry provided improved accuracy and interobserver reliability. AI-based methods demonstrated the highest precision by minimizing subjectivity and enhancing standardization.

CONCLUSION

Objective measurement techniques, particularly smartphone-based and AI-driven approaches, are superior to UVI in assessing penile curvature in hypospadias. Future advances in AI technology and digital imaging may further refine VC assessment, leading to improved surgical outcomes. Adoption of standardized, objective measurement methods should be encouraged in clinical practice.

Для цитирования: Babu Ramesh, Chandrasekharam Vvs, Abbas Tariq O. Objective assessment of penile curvature in hypospadias: A narrative review.. Journal of pediatric urology. 2025. DOI: 10.1016/j.jpurol.2025.05.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.