MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0284185118788896

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2018

Third generation dual-energy CT with 80/150 Sn kV for head and neck tumor imaging.

Suntharalingam Saravanabavaan, Stenzel Elena, Wetter Axel, Guberina Nika, Umutlu Lale, Schlosser Thomas, Nassenstein Kai

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Dual-energy CT (DECT) provides additional image datasets which enable improved tumor delineation or reduction of beam hardening artifacts in patients with head and neck squamous cell carcinoma (SCC).

PURPOSE: To assess radiation dose and image quality of third-generation DECT of the head and neck in comparison to single-energy CT (SECT).

MATERIAL AND

METHODS

Thirty patients with SCC who underwent both SECT (reference tube voltage 120 kVp) and DECT (80/150 Sn kVp) of the head and neck region for staging were retrospectively selected. Attenuation measurements of the sternomastoid muscle, internal jugular vein, submandibular gland and tongue were compared. Image noise was assessed at five anatomic levels. Subjective image quality was evaluated by two radiologists in consensus.

RESULTS

CTDIvol was 55% lower with DECT (4.2 vs. 9.3 mGy; P = 0.002). Median image noise was equal or lower in DECT at all levels (nasopharynx: 3.9 vs. 5.8, P < 0.0001; floor of mouth: 3.6 vs. 4.5, P = 0.0002; arytenoids: 3.6 vs. 3.1, P = 0.096; lower thyroid: 4.4 vs. 5.7, P = 0.002; arch of aorta: 5.6 vs. 6.5, P = 0.001). Attenuation was significantly lower in DECT ( P < 0.05). Subjective image analysis revealed that DECT is equal or superior to SECT with regard to overall image quality (nasopharynx: 5 vs. 5, P = 1; floor of mouth: 5 vs. 5, P = 0.0041; arytenoids: 5 vs. 5, P = 0.6; lower thyroid: 5 vs. 3, P < 0.0001; arch of aorta: 5 vs. 4, P < 0.0001).

CONCLUSION

Head and neck imaging with third-generation DECT can reduce radiation dose by half compared to SECT, while maintaining excellent image quality.

Для цитирования: Suntharalingam Saravanabavaan, Stenzel Elena, Wetter Axel, Guberina Nika, Umutlu Lale, Schlosser Thomas, Nassenstein Kai. Third generation dual-energy CT with 80/150 Sn kV for head and neck tumor imaging.. Acta radiologica (Stockholm, Sweden : 1987). 2018. DOI: 10.1177/0284185118788896.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.