MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-022-08868-3

Медицинская библиотека · European radiology · 2022

Contrast-enhanced mammography for the assessment of screening recalls: a two-centre study.

Cozzi Andrea, Schiaffino Simone, Fanizza Marianna, Magni Veronica, Menicagli Laura, Monaco Cristian Giuseppe, Benedek Adrienn, Spinelli Diana, Di Leo Giovanni, Di Giulio Giuseppe, Sardanelli Francesco

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the potential of contrast-enhanced mammography (CEM) for reducing the biopsy rate of screening recalls.

METHODS

Recalled women were prospectively enrolled to undergo CEM alongside standard assessment (SA) through additional views, tomosynthesis, and/or ultrasound. Exclusion criteria were symptoms, implants, allergy to contrast agents, renal failure, and pregnancy. SA and CEM were independently evaluated by one of six radiologists, who recommended biopsy or 2-year follow-up. Biopsy rates according to SA or recombined CEM (rCEM) were compared with the McNemar's test. Diagnostic performance was calculated considering lesions with available final histopathology.

RESULTS

Between January 2019 and July 2021, 220 women were enrolled, 207 of them (median age 56.6 years) with 225 suspicious findings analysed. Three of 207 patients (1.4%) developed mild self-limiting adverse reactions to iodinated contrast agent. Overall, 135/225 findings were referred for biopsy, 90/225 by both SA and rCEM, 41/225 by SA alone and 4/225 by rCEM alone (2/4 being one DCIS and one invasive carcinoma). The rCEM biopsy rate (94/225, 41.8%, 95% CI 35.5-48.3%) was 16.4% lower (p < 0.001) than the SA biopsy rate (131/225, 58.2%, 95% CI 51.7-64.5%). Considering the 124/135 biopsies with final histopathology (44 benign, 80 malignant), rCEM showed a 93.8% sensitivity (95% CI 86.2-97.3%) and a 65.9% specificity (95% CI 51.1-78.1%), all 5 false negatives being ductal carcinoma in situ detectable as suspicious calcifications on low-energy images.

CONCLUSIONS

Compared to SA, the rCEM-based work-up would have avoided biopsy for 37/225 (16.4%) suspicious findings. Including low-energy images in interpretation provided optimal overall CEM sensitivity.

KEY POINTS: • The work-up of suspicious findings detected at mammographic breast cancer screening still leads to a high rate of unnecessary biopsies, involving between 2 and 6% of screened women. • In 207 recalled women with 225 suspicious findings, recombined images of contrast-enhanced mammography (CEM) showed a 93.8% sensitivity and a 65.9% specificity, all 5 false negatives being ductal carcinoma in situ detectable on low-energy images as suspicious calcifications. • CEM could represent an easily available one-stop shop option for the morphofunctional assessment of screening recalls, potentially reducing the biopsy rate by 16.4%.

Для цитирования: Cozzi Andrea, Schiaffino Simone, Fanizza Marianna, Magni Veronica, Menicagli Laura, Monaco Cristian Giuseppe, Benedek Adrienn, Spinelli Diana, Di Leo Giovanni, Di Giulio Giuseppe, Sardanelli Francesco. Contrast-enhanced mammography for the assessment of screening recalls: a two-centre study.. European radiology. 2022. DOI: 10.1007/s00330-022-08868-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.