[Shang Ring versus disposable circumcision suture device in the treatment of phimosis or redundant prepuce].
Аннотация
OBJECTIVE
To compare the clinical efficiency of Shang Ring with that of the disposable circumcision suture device (DCSD) in the treatment of phimosis or redundant prepuce.
METHODS
From June 2013 to March 2015, we treated 320 patients with phimosis or redundant prepuce using Shang Ring (n=158) or DCSD (n=162). We compared the operation time, intra-operative blood loss, incision healing time, postoperative complications, postoperative satisfaction, and treatment cost between the two groups of patients.
RESULTS
Comparison between the Shang Ring and DCSD groups showed that the operation time was (5.6±1.3) vs (5.4±1.2) min, intra-operative blood loss (1.2±0.8) vs (1.3±0.9) ml, postoperative delayed hemorrhage 3.16% (5/158) vs 4.32% (7/162), incision healing time (16.1±7.2) vs (7.5±2.3) d, wound infection 15.82% (25/158) vs 7.41% (12/162), 1-month postoperative incision edema 29.11% (46/158) vs 9.26% (15/162), overall postoperative satisfaction rate 63.92% (101/158) vs 90.12% (146/162), and treatment cost (1121.2±15.6) vs (2142.6±10.8) RMB ¥. There were statistically significant differences between the two groups in the latter five parameters (P<0.05 ), but not in the first three (P>0.05 ).
CONCLUSIONS
The DSCD has an obvious superiority over Shang Ring for its relatively lower complication rate, shorter incision healing time, and better cosmetic appearance.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.