McLean Jake B, Larsen Brian G, Weathersby Ethan J, Carter Bs Ryan V, Allyn Katheryn J, Garbini Joseph L, Sanders Joan E
Аннотация
BACKGROUND: Management of fluid in the limbs is a challenge faced by people with disabilities. In prosthetics, a means for transtibial prosthesis users to stabilize their residual limb fluid volume during the day may improve socket fit.
OBJECTIVE: To determine if releasing the panels and locking pin of a cabled-panel adjustable socket during socket release significantly improved limb fluid volume recovery and retention over releasing the panels alone.
DESIGN: Repeated-measures experiment to assess the effects on limb fluid volume retention.
SETTING: Participants were tested in a laboratory setting while walking on a treadmill.
INTERVENTION: Release of a locking pin tether during sitting as a limb volume accommodation strategy.
MAIN OUTCOME MEASURE: Percent limb fluid volume retention for panel and pin release compared with panel release alone at 2 minutes (short term) and 50 minutes (long term) after subsequent activity. Limb fluid volume was monitored using bioimpedance analysis.
RESULTS: Median percent limb fluid volume retention for the panel and pin release was significantly greater than panel release alone for both anterior and posterior regions for the long term (P = .0499 and .0096, respectively) but not the short term (P = .0712 and .1580, respectively).
CONCLUSION: Augmenting panel release with pin release may be an effective accommodation strategy for prosthesis users with transtibial amputation to better retain limb fluid volume.
OBJECTIVE: To determine if releasing the panels and locking pin of a cabled-panel adjustable socket during socket release significantly improved limb fluid volume recovery and retention over releasing the panels alone.
DESIGN: Repeated-measures experiment to assess the effects on limb fluid volume retention.
SETTING: Participants were tested in a laboratory setting while walking on a treadmill.
INTERVENTION: Release of a locking pin tether during sitting as a limb volume accommodation strategy.
MAIN OUTCOME MEASURE: Percent limb fluid volume retention for panel and pin release compared with panel release alone at 2 minutes (short term) and 50 minutes (long term) after subsequent activity. Limb fluid volume was monitored using bioimpedance analysis.
RESULTS: Median percent limb fluid volume retention for the panel and pin release was significantly greater than panel release alone for both anterior and posterior regions for the long term (P = .0499 and .0096, respectively) but not the short term (P = .0712 and .1580, respectively).
CONCLUSION: Augmenting panel release with pin release may be an effective accommodation strategy for prosthesis users with transtibial amputation to better retain limb fluid volume.