m+Medelevator.RU
← Поиск публикаций
Neuromodulation : journal of the International Neuromodulation Society · 2026

Optimizing Percutaneous Tibial Nerve Stimulation Intensity for Overactive Bladder Using a Motion Capture System.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jin Linquan, Shang Dongsheng, Deng Han, Li Chen, Wang Ziyu, Li Hao, Liao Limin, Guo Yun, Li Xing

Аннотация

BACKGROUND AND OBJECTIVE: Overactive bladder (OAB) is a significant global health issue. The standard percutaneous tibial nerve stimulation (PTNS) protocol uses maximal-tolerance stimulation and causes discomfort and other side effects. This study aimed to optimize stimulation intensity using a motion capture (MoCap) system, thereby enhancing therapy safety and personalization.

MATERIALS AND METHODS: In a single short-term stimulation session, the stimulator was fixed to the cat's (four males and four females) medial malleolus and the inertial measurement unit (IMU) sensor to the ipsilateral paw dorsum. Threshold intensity T was established conventionally by visual observation of toe flexion, and t was established through MoCap. The effects of PTNS on the micturition reflex were assessed using serial cystometrograms (CMGs) during infusion of normal saline (NS) or acetic acid (AA).

RESULTS: During NS infusion, PTNS at 2T increased bladder capacity (BC) to 143.60% ± 4.96% of control (9.89 ± 3.20 mL) and at 2t increased it to 143.10% ± 5.81% (both p < 0.01). During AA infusion, BC decreased to 56.43% ± 1.59% of control (p < 0.01); subsequent PTNS at 2T and at 2t restored it to 77.99% ± 4.80% and 78.08% ± 4.65%, respectively (both p < 0.01). MoCap t was significantly lower than T (p < 0.05). Both intensities prolonged contraction duration relative to the AA group (p < 0.05), whereas contraction amplitude and area under the curve did not differ among conditions (p > 0.05). Angular velocity and linear acceleration across all three orthogonal axes showed moderately to highly significant positive correlations with stimulation intensity.

CONCLUSIONS: The IMU-based MoCap system used angular velocity and linear acceleration as measures and identified a markedly lower stimulation threshold that produced therapeutic outcomes equivalent to conventional protocols. Although this single-session short-term study differs from standard longitudinal clinical application, this approach reduces stimulation intensity and may enable safer and more individualized PTNS for OAB.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты