MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2024.05.180

Медицинская библиотека · World neurosurgery · 2024

Use of the Scepter Dual-Lumen Balloon Catheter for Transarterial Onyx Embolization of Cranial Dural Arteriovenous Fistulas.

Kaul Anand, Roy Joanna M, El Naamani Kareem, Ahmed Meah T, Carreras Angeleah, Mouchtouris Nikolaos, Sizdahkhani Saman, Majmundar Shyam, Ghanem Marc, Gooch Michael R, Herial Nabeel A, Jabbour Pascal, Rosenwasser Robert H, Tjoumakaris Stavropoula I

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Dual-lumen balloon microcatheters allow for controlled anterograde flow of Onyx while providing proximal flow arrest, thereby obviating the need for a second microcatheter or Onyx plug formation. We sought to assess the safety and efficiency of the Scepter dual-lumen balloon microcatheter in trans arterial Onyx embolization of intracranial dural arteriovenous fistulas (DAVFs).

METHODS

We conducted a retrospective study of 36 patients with cranial DAVFs in which a Scepter balloon microcatheter was used between 2016 and 2023.

RESULTS

Our study comprised 36 patients, mostly male (n = 23, 63.8%) with a mean age of 60.8 years. Most DAVFs were in the occipital lobe (n = 24, 66.7%), and 50% had external carotid artery supply from the occipital artery. Eighteen (50%) of DAVFs were Cognard type III and IV, respectively. About one third (33.3%, n = 12) of the DAVFs drained into the transverse sigmoid junction, and 27.7% (n = 10) had direct cortical venous drainage into supratentorial or posterior fossa veins. Complete occlusion was obtained in 22 (61.1%) patients while partial occlusion was observed in 14 (38.9%) patients. One patient (2.8%) developed a retroperitoneal hematoma. At final follow-up, complete occlusion was observed in 21 (77.8%) and partial occlusion was observed in 8 (22.2%). Recurrence was observed in 4/30 (13.3%) patients, and retreatment was required in 6 (18.75%) cases.

CONCLUSIONS

At midterm follow-up, our study showed low morbidity and modest complete occlusion rates using the Scepter for transarterial Onyx embolization of high-grade DAVFs.

Для цитирования: Kaul Anand, Roy Joanna M, El Naamani Kareem, Ahmed Meah T, Carreras Angeleah, Mouchtouris Nikolaos, Sizdahkhani Saman, Majmundar Shyam, Ghanem Marc, Gooch Michael R, Herial Nabeel A, Jabbour Pascal, Rosenwasser Robert H, Tjoumakaris Stavropoula I. Use of the Scepter Dual-Lumen Balloon Catheter for Transarterial Onyx Embolization of Cranial Dural Arteriovenous Fistulas.. World neurosurgery. 2024. DOI: 10.1016/j.wneu.2024.05.180.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.