MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/0115734056284650240325044027

Медицинская библиотека · Current medical imaging · 2024

Feasibility of Amide Proton Transfer-Weighted Imaging at 3T for Renal Masses: A Preliminary Study.

Xu Yun, Wan Qingxuan, Ren Xihui, Jiang Yutao, Yao Jing, Wu Peng, Shen Aijun, Wang Peijun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To investigate the optimal B1,rms value of renal amide proton transfer-weighted (APTw) images and the reproducibility of this value, and to explore the utility of APT imaging of renal masses and kidney tissues.

METHODS

APTw images with different B1,rms values were repeatedly recorded in 15 healthy volunteers to determine the optimal value. Two 4-point Likert scales (poor [1] to excellent [4]) were used to evaluate contour clarity and artifacts in masses and normal tissues. The APTw values of masses and normal tissues were then compared in evaluable images (contour clarity score > 1, artifacts score > 1). The APTw of malignant masses, normal tissues, and benign masses were calculated and compared with the Mann-Whitney U test.

RESULTS

The optimal scanning parameter of B1,rms was 2 μT, and the APTw images had good agreement in the volunteers. Our study of APTw imaging examined 70 renal masses (13 benign, 57 malignant) and 49 normal kidneys (including those from 15 healthy volunteers). The mean APTw value for renal malignant masses (2.28(1.55)) was different from that for benign masses (0.91(1.30)) (P<0.001), renal cortex (1.30 (1.25)) (P<0.001), renal medulla (1.64 (1.33)) (P<0.05), and renal pelvis (5.49 (2.65)) (P<0.001).

CONCLUSION

These preliminary data demonstrate that APTw imaging of the kidneys has potential use as an imaging biomarker for the differentiation of normal tissues, malignant masses, and benign masses.

Для цитирования: Xu Yun, Wan Qingxuan, Ren Xihui, Jiang Yutao, Yao Jing, Wu Peng, Shen Aijun, Wang Peijun. Feasibility of Amide Proton Transfer-Weighted Imaging at 3T for Renal Masses: A Preliminary Study.. Current medical imaging. 2024. DOI: 10.2174/0115734056284650240325044027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.