MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua nan ke xue = National journal of andrology · 2015

[Modified circumcision with a disposable suture device].

Ren Yu, Yan Jia-jun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To improve the methods and reduce the complications of circumcision with a disposable suture device.

METHODS

This study included 325 male patients aged 14-65 (mean 28.9) years, treated for redundant prepuce or phimosis by modified (n = 201) or conventional circumcision with a disposable suture device (n = 124). We compared the incidence of complications and the patients' satisfaction between the two surgical methods.

RESULTS

Compared with conventional circumcision, the modified method showed a significantly lower incidence of postoperative bleeding (14.52% vs 2.49% , P < 0.05) and a lower rate of second surgery for penile hematoma (4.03% vs 0.50%, P < 0.05). The patients' satisfaction was markedly higher with the modified method (91.94%) than with conventional circumcision (97.51%) (P < 0.05).

CONCLUSION

Modified circumcision with the disposable suture device can significantly reduce the incidence of postoperative bleeding and penile hematoma and therefore deserves wide clinical application.

Для цитирования: Ren Yu, Yan Jia-jun. [Modified circumcision with a disposable suture device].. Zhonghua nan ke xue = National journal of andrology. 2015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.