MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/1744-9987.70052

Медицинская библиотека · Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2025

Biomarkers Related to Peritoneal Transfer Function and Dialysis Adequacy.

Pu Shuyi, Song Shiyi, Jia Xiaomin, Wang Ji

СтатьяОбзорПеревод в очереди

Аннотация

The main treatment for end-stage renal disease (ESRD) is renal replacement therapy, among which peritoneal dialysis (PD) is easy to perform, inexpensive, and widely used. The internationally adopted Peritoneal Equilibration Test (PET) categorizes peritoneal function into four types based on the dialysate-to-plasma creatinine ratio (D/Pcr). In some patients undergoing long-term PD, changes in peritoneal function lead to a decline in dialysis adequacy, which ultimately results in withdrawal from PD. Among these patients, those with high-transport peritoneal function exhibit higher mortality rates and poorer prognoses compared to patients with low-transport peritoneal function. However, PET fails to identify underlying pathologies (e.g., fibrosis, inflammation). Similarly, dialysis adequacy tests also fail to reveal the underlying causes of changes in dialysis adequacy. Therefore, early identification of the underlying causes of peritoneal function changes and timely clinical interventions may prolong the duration of PD. This review lists biomarkers related to peritoneal transport function that may indicate the causes of altered peritoneal function and could guide clinical treatment protocols in the future.

Для цитирования: Pu Shuyi, Song Shiyi, Jia Xiaomin, Wang Ji. Biomarkers Related to Peritoneal Transfer Function and Dialysis Adequacy.. Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy. 2025. DOI: 10.1111/1744-9987.70052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.