DOI 10.1016/j.bjps.2012.01.025
Transzygomatic Kirschner wire fixation for the treatment of blowout fracture.
Аннотация
BACKGROUND
Total orbital floor reconstruction with sheet-shape materials is available for the treatment of extensive and crushed-type blowout fractures. Simple blowout fractures, on the other hand, require only manual reduction without fixation. Although several types of blowout fractures do not require total reconstruction, some fixation is usually necessary.
METHODS
Eighteen cases of blowout fracture were treated with transzygomatic Kirschner wire fixation between 2002 and 2009. This technique was applied to simple fracture cases in which periorbital soft tissue re-herniated through the floor defect into the maxillary sinus after manual reduction, despite improvement of the extra-ocular muscle entrapment. The wire was used to directly support the fracture segment in five cases and used together with a maxillary sinus anterior wall bone graft in 13 cases.
RESULTS
Mean follow-up was 12.5 months. Mild diplopia remained as a subjective symptom in one case. None of the cases developed major complications or conspicuous scars on the cheek.
CONCLUSIONS
Transzygomatic Kirschner wire fixation for blowout fracture has the advantages of precise and rigid fixation of all parts of the inferior floor, minimal morbidity without requiring an orbital approach and long-term safety without artificial remnants. This technique can be applied for the treatment of simple blowout fractures.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.