m+Medelevator.RU
← Поиск публикаций
Therapeutic advances in gastroenterology · 2026

Impact of wet suction on specimen quality and diagnostic accuracy in EUS-guided tissue acquisition: a systematic review and meta-analysis of randomized controlled trials.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Huang Po-Feng, Lin Jung-Chun, Huang Tien-Yu, Chen Peng-Jen, Yang Chi-Wei, Kuo Yu-Ting, Chen Hsuan-Wei

Аннотация

BACKGROUND AND AIMS: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is critical for diagnosing solid lesions. The wet-suction technique, which pre-fills the needle lumen with saline, has been proposed to improve specimen quality compared with conventional dry suction. This study aimed to evaluate the efficacy of wet suction versus dry suction in EUS-TA.

OBJECTIVES: This study aimed to evaluate the efficacy of wet suction versus dry suction in EUS-TA.

DESIGN: We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) following PRISMA 2020 guidelines.

METHODS: Electronic searches of PubMed, Embase, Cochrane CENTRAL, and additional databases were performed through January 2025. Primary outcomes were blood contamination, cellularity, and integrity scores; secondary outcomes were diagnostic accuracy and specimen adequacy. Effect sizes were calculated using Hedges' g or risk ratios (RRs) with 95% confidence intervals (CIs).

RESULTS: Seven RCTs (784 patients; 1566 specimens) were included. Wet suction significantly reduced blood contamination (Hedges' g = 0.289, 95% CI: 0.178-0.401, p < 0.0001) and improved cellularity (Hedges' g = 0.420, 95% CI: 0.241-0.599, p < 0.0001) with low heterogeneity. Integrity score showed no significant difference (p = 0.054). Overall diagnostic accuracy was similar between techniques (RR = 1.025, p = 0.548), but subgroup analysis revealed higher accuracy for wet suction in EUS-fine needle aspiration (FNA; RR = 1.162, p = 0.001). Specimen adequacy did not differ significantly (p = 0.074).

CONCLUSION: Wet suction improves sample quality by reducing blood contamination and increasing cellularity, with potential diagnostic benefit in FNA procedures. Effects on integrity and adequacy remain inconclusive. Larger, standardized trials are warranted to confirm these findings.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты