Hanazaki Kazuhiro, Kitagawa Hiroyuki, Yatabe Tomoaki, Munekage Masaya, Dabanaka Ken, Takezaki Yuka, Tsukamoto Yuuki, Asano Takuji, Kinoshita Yoshihiko, Namikawa Tsutomu
Аннотация
BACKGROUND: We examined whether perioperative intensive insulin therapy (IIT) using an artificial pancreas (AP) with a closed-loop glycemic control system can be used to prevent hypoglycemia in surgical patients.
METHODS: Between 2006 and 2012, perioperative glycemic control using an AP was performed in 427 patients undergoing general surgery. A total of 305 patients undergoing IIT using an AP in the target blood glucose range of 80 to 110 mg/dL were enrolled in the study. Data were collected prospectively and were reviewed or analyzed retrospectively.
RESULTS: No patients had hypoglycemia. Perioperative mean blood glucose level and achievement rates in target blood glucose range of 80 to 110 mg/dL were 100.5 ± 11.9 mg/dL and 88.1% ± 16.0%, respectively. For the 3 primary operative methods, including hepatic, pancreatic, and esophageal resections, there were no significant differences in glycemic control stability between the types of surgery.
CONCLUSION: Perioperative IIT using an AP with a closed-loop glycemic control system can be used to prevent hypoglycemia and maintain stable glycemic control with less variability of blood glucose concentration.
METHODS: Between 2006 and 2012, perioperative glycemic control using an AP was performed in 427 patients undergoing general surgery. A total of 305 patients undergoing IIT using an AP in the target blood glucose range of 80 to 110 mg/dL were enrolled in the study. Data were collected prospectively and were reviewed or analyzed retrospectively.
RESULTS: No patients had hypoglycemia. Perioperative mean blood glucose level and achievement rates in target blood glucose range of 80 to 110 mg/dL were 100.5 ± 11.9 mg/dL and 88.1% ± 16.0%, respectively. For the 3 primary operative methods, including hepatic, pancreatic, and esophageal resections, there were no significant differences in glycemic control stability between the types of surgery.
CONCLUSION: Perioperative IIT using an AP with a closed-loop glycemic control system can be used to prevent hypoglycemia and maintain stable glycemic control with less variability of blood glucose concentration.