International braz j urol : official journal of the Brazilian Society of Urology · 2026
Robot-Assisted Boari-flap after Orthotopic Neobladder Using the KangDuo Surgical Robot-01 System.
СтатьяКлинический случайVideo-Audio MediaНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Han Guanpeng, Wang Xiang, Li Zhihua, Yang Kunlin, Zhou Liqun, Li Xuesong
Аннотация
PURPOSE: Benign ureteroenteric anastomosis stricture (BUES) is a well-recognized long-term complication following urinary diversion (1). While endourological interventions are often first-line, their success rates are limited (2, 3). Open uretero-ileal reimplantation remains the gold standard but is technically challenging and carries high complication risks (2). Robotic surgery offers a promising alternative with comparable success rates and minimally invasive benefits (4). In addition to the da Vinci® system, several new surgical robotic systems have been developed, demonstrating comparable safety and efficacy (5-7). This study reports our experience with robotic-assisted Boari-flap using the KangDuo-Surgical-Robot-01 (KD-SR-01) System in managing long-segment BUES after radical cystectomy with orthotopic neobladder.
MATERIALS AND METHODS: A 64-year-old man developed left BUES 2.5 years after robot-assisted radical cystectomy with orthotopic neobladder. After nephrostomy drainage for 6 months, a robotic-assisted Boari-flap was performed using the KD-SR-01 system in the Trendelenburg position. Surgical steps included: neobladder mobilization, distal ureter dissection, neobladder flap creation, ureter-flap anastomosis, and flap tubularization.
RESULTS: Surgery was successful without conversion. The stricture length was 5 cm. The neobladder flap measured 5 × 3 cm (length × width). Operating time was 145 minutes, with 30 mL of blood loss. The nephrostomy tube and double-J stent were removed two months postoperatively. At three-month follow-up, the patient remained asymptomatic with stable serum creatinine. Cine magnetic resonance urography demonstrated normal ureteral peristalsis and ureteral jets. No postoperative complications occurred.
CONCLUSIONS: Robotic-assisted Boari-flap after radical cystectomy with orthotopic neobladder is technically feasible. A larger cohort with longer follow-up is necessary to assess its safety and effectiveness.
MATERIALS AND METHODS: A 64-year-old man developed left BUES 2.5 years after robot-assisted radical cystectomy with orthotopic neobladder. After nephrostomy drainage for 6 months, a robotic-assisted Boari-flap was performed using the KD-SR-01 system in the Trendelenburg position. Surgical steps included: neobladder mobilization, distal ureter dissection, neobladder flap creation, ureter-flap anastomosis, and flap tubularization.
RESULTS: Surgery was successful without conversion. The stricture length was 5 cm. The neobladder flap measured 5 × 3 cm (length × width). Operating time was 145 minutes, with 30 mL of blood loss. The nephrostomy tube and double-J stent were removed two months postoperatively. At three-month follow-up, the patient remained asymptomatic with stable serum creatinine. Cine magnetic resonance urography demonstrated normal ureteral peristalsis and ureteral jets. No postoperative complications occurred.
CONCLUSIONS: Robotic-assisted Boari-flap after radical cystectomy with orthotopic neobladder is technically feasible. A larger cohort with longer follow-up is necessary to assess its safety and effectiveness.