MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jfo.2010.01.013

Медицинская библиотека · Journal francais d'ophtalmologie · 2010

Pushed monocanalicular intubation: a preliminary report.

Fayet B, Racy E, Renard G

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the behavior of a "pushed" monocanalicular stent by means of nasal endoscopy.

PATIENTS AND

METHODS

Four children (six affected sides) with congenital nasolacrimal duct obstruction were treated with monocanalicular intubation with an anchoring plug. The children's mean age at the time of the operation was 33 months (range, 30-37 months). The procedure began with probing in order to verify (a) dacryostenosis (simple or extensive nasolacrimal duct impatency) and (b) the metal-to-metal contact in the lower nasal meatus. The stent was similar to a Monoka(TM), but the guide (a malleable stainless steel probe) is located inside the silicone stent rather than projecting from it. The silicone's total length is 40 mm and the external diameter 0.96 mm. Simultaneously, the guide acts to catheterize the nasolacrimal duct by pushing the silicone through the upper and lower parts of the outflow system. The guide is removed via a punctal approach. This mode of intubation dispenses with the nasal recovery step. Nasal endoscopy was used to monitor (a) the position of the stent in the lower nasal meatus (free or submucosal), (b) mucosal damage and bleeding, and (c) the behavior of the silicone tube during removal of the guide.

RESULTS

Because of the complexity of nasolacrimal ducts, two of the six sides were treated with the classical Monoka intubation method of pulling the silicone tubing out from the nasal exit of the duct (the pull technique). The pushed intubation method was used for the four simple nasolacrimal stenoses, with no problems whatsoever. In all four cases, endoscopic examination showed (a) no submucosal tunneling (false passage), (b) no noteworthy mucosal damage, and (c) no retraction (bunch-up) of the silicone tube during the metal guide removal. No particular complications were reported during the procedure or the intubation period, which lasted an average of 3 weeks. The stents were removed in the consulting room. Tearing ceased during the 1(st) week in two cases, during the intubation period. Tearing persisted throughout the intubation period in the other two cases, but ceased during the week following stent removal. The follow-up lasted 2 months.

CONCLUSIONS

The pushed procedure simplifies monocanalicular nasal intubation. Its indications remain to be determined.

Для цитирования: Fayet B, Racy E, Renard G. Pushed monocanalicular intubation: a preliminary report.. Journal francais d'ophtalmologie. 2010. DOI: 10.1016/j.jfo.2010.01.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.