MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2015.11.032

Медицинская библиотека · Biosensors & bioelectronics · 2015

Differential detection of a surrogate biological threat agent (Bacillus globigii) with a portable surface plasmon resonance biosensor.

Adducci Benjamin A, Gruszewski Hope A, Khatibi Piyum A, Schmale David G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

New methods and technology are needed to quickly and accurately detect potential biological warfare agents, such as Bacillus anthracis, causal agent of anthrax in humans and animals. Here, we report the detection of a simulant of B. anthracis (B. globigii) alone and in a mixture with a different species of Bacillus to test non-specific interference using a portable surface plasmon resonance (SPR) biosensor (SPIRIT 4.0, Seattle Sensor Systems). Both direct capture and antibody amplification were used to determine the limit of detection for spores of B. globigii, and to detect spores of B. globigii in a mixed sample containing another Bacillus spp. Spores of B. globigii were detected by anti-B. globigii (anti-Bg) coated sensors by direct capture at a concentration of 10(7)spores/mL, and with a secondary antibody amplification at a concentration of 10(5)spores/mL. Spores of B. globigii were differentially detected in a 1:1 mixture with B. pumilus spores from equal concentrations (10(7)spores/mL) with a secondary antibody amplification. To our knowledge, this is the first report of the differential detection of B. globigii with SPR in a mixed sample containing at least one additional Bacillus spp., highlighting the potential for SPR to detect any target bacterium in a mixed sample of closely related species. With the availability of portable instrumentation to accurately detect biological warfare agents such as B. anthracis, emergency responders can implement protocols in a timely fashion, limiting the amount of exposed individuals.

Для цитирования: Adducci Benjamin A, Gruszewski Hope A, Khatibi Piyum A, Schmale David G. Differential detection of a surrogate biological threat agent (Bacillus globigii) with a portable surface plasmon resonance biosensor.. Biosensors & bioelectronics. 2015. DOI: 10.1016/j.bios.2015.11.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.