MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/sur.2024.075

Медицинская библиотека · Surgical infections · 2024

Practicability of Serum Kallistatin Levels as a Biomarker in the Diagnosis of Tubo-Ovarian Abscess.

Birsen Meryem Busra, Erturk Derya, Onder Durmuş, Eryilmaz Ahmet Ilker, Kaba Metin, Ellidag Hamit Yasar, Inal Hasan Ali

СтатьяПеревод в очереди

Аннотация

Objective

This study investigates the practicability of serum kallistatin as a biomarker in the diagnosis of tubo-ovarian abscess (TOA) because C-reactive protein (CRP) is insufficiently specific for diagnosis.

Methods

Thirty patients (control group) who presented for elective gynecological surgeries and 30 who were hospitalized due to TOA (study group) at the Antalya Training and Research Hospital Gynecology Clinic, Türkiye, between January 1 and December 31, 2022, were included in the study. Blood samples were collected for the calculation of complete blood count, biochemistry, CRP, and serum kallistatin values, and the results were recorded in a database.

Results

Although no significant differences were observed between the control and study groups in terms of age or body mass index, significant differences were observed in terms of marital status, number of pregnancies, parity number, intrauterine device history, and previous surgical history (p > 0.05). Serum hemoglobin levels (12.61 ± 1.30 vs. 11.47 ± 1.77; p = 0.008), white blood cell (7.9 [6.15 ± 9.7] vs. 17.0 [11.6-19.6]; p < 0.001), neutrophil (4.6 [3.6-6.12] vs. 13.6 [9.25-16.1]; p < 0.001), lymphocyte (2.51 ± 0.71 vs. 2.33 ± 0.69; p = 0.307), and platelet counts (285.63 ± 78.0 vs. 407.03 ± 131.96; p < 0.001), neutrophil-lymphocyte ratio (2.11 ± 0.93 vs. 6.18 ± 2.20; p < 0.001), neutrophil-lymphocyte ratio (123.16 ± 52.63 vs. 184.39 ± 63.90; p < 0.001), hs-CRP (1.20 [5.55-1.92] vs. 240 [138.25-291.0]; p < 0.001), kallistatin (7.18 ± 3.15 vs. 3.83 ± 3.69; p = 0.006), and urine leukocyte values (1 [0.75-3] vs. 3 [1-6.5]; p = 0.038) also differed significantly between the control and study groups.

Conclusion

The study findings show that serum kallistatin levels can be used as a biomarker in the diagnosis of TOA. Further studies involving more participants are now needed to test the accuracy of our results.

Для цитирования: Birsen Meryem Busra, Erturk Derya, Onder Durmuş, Eryilmaz Ahmet Ilker, Kaba Metin, Ellidag Hamit Yasar, Inal Hasan Ali. Practicability of Serum Kallistatin Levels as a Biomarker in the Diagnosis of Tubo-Ovarian Abscess.. Surgical infections. 2024. DOI: 10.1089/sur.2024.075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.