MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ymeth.2026.09.003

Медицинская библиотека · Methods (San Diego, Calif.) · 2026

Fragment morphometry analysis and same-color-channel separation enable reproducible quantification across BBB models.

Peck Benjamin D, O'Hare Nicholas R, Ferris Craig F, Pinals Rebecca L, Ebong Eno E

СтатьяПеревод в очереди

Аннотация

Quantifying blood-brain barrier (BBB) integrity from fluorescence microscopy remains limited by subjective scoring and categorical classification methods that lack reproducibility. For reproducible BBB phenotyping, we present two semi-automated image-analysis pipelines that replace manual scoring with quantitative, continuous-variable measurements. Our in vitro pipeline, implemented in Python, quantifies the connectivity of tight junction structures by measuring discrete ZO-1 fragment objects within manually traced junction regions. It outputs continuous metrics including average fragment area, total junctional area, and a junctional fragmentation ratio that captures degree of ZO‑1 continuity. In human brain microvascular endothelial cells subjected to glycocalyx component knockdown, the pipeline detected significantly reduced fragment area (37% decrease for both CD44 and syndecan-1 (SDC1) knockdown, p = 0.0148 and 0.0084) and junctional fragmentation ratio (p = 0.0061 and 0.0137). Our in vivo pipeline integrates ilastik-based pixel classification with FIJI macro automation to quantify vascular marker colocalization and to separate vessel signal from microglial contamination within a single fluorescence channel, eliminating the need for dedicated counterstains. Applied across four mouse cohorts [young, aged, Alzheimer's, traumatic brain injury (TBI)] and three brain regions [prefrontal cortex (PFC), hippocampus, midbrain], the pipeline detected concurrent ZO-1 loss and ICAM-1 elevation in the PFC and hippocampus of aged and Alzheimer's cohorts, which were statistically indistinguishable, with eNOS nearly doubling in the Alzheimer's PFC (p = 0.0013). TBI mice showed persistent ZO-1 loss with transient ICAM-1 and eNOS changes. Both deterministic pipelines are available on GitHub and designed for adoption beyond the specific markers and systems analyzed here.

Для цитирования: Peck Benjamin D, O'Hare Nicholas R, Ferris Craig F, Pinals Rebecca L, Ebong Eno E. Fragment morphometry analysis and same-color-channel separation enable reproducible quantification across BBB models.. Methods (San Diego, Calif.). 2026. DOI: 10.1016/j.ymeth.2026.09.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.