A Modified Lateral Seminal Vesicle Approach Preserving the Bladder Neck in Laparoscopic Radical Prostatectomy Improves Urinary Continence Recovery.
Аннотация
AIM: The purpose of this study was to investigate the effect of laparoscopic lateral seminal vesicle approach to preserve the bladder neck during laparoscopic radical prostatectomy.
METHODS
Between September 2020 and December 2022, we retrospectively analyzed patients with T1-T3b stage prostate cancer treated at our institution using the laparoscopic lateral seminal vesicle approach. We recorded the bladder neck preservation success rate, cystourethral anastomosis time, urinary catheter extraction time, length of hospital stay, and urinary control scores, including urine pad use, at 1 week, 1 month, and 3 months post-catheter removal. Adverse events included rectal injury, bladder injury, ureteral injury and positive surgical margins.
RESULTS
There were 56 patients (mean age 70 ± 5.8 years) The success rate of bladder neck preservation was 100%. The median cystourethral anastomosis time was 11 (9-14) minutes. The median postoperative hospital stay was 10 (9-11) days. The urinary continence rate was 83.9% (47/56) in 1 week, 89.3% (50/56) in 1 month and 98.2% (55/56) in 3 months. One patient developed adhesions caused by invasion of both seminal vesicles, which damaged the rectal wall.
CONCLUSIONS
The laparoscopic lateral seminal vesicle approach can preserve the bladder neck completely during laparoscopic radical prostatectomy, improving postoperative urinary continence, with a high rate of immediate urinary continence, and significantly improving patients' quality of life.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.