MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compmedimag.2024.102469

Медицинская библиотека · Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2024

Cervical OCT image classification using contrastive masked autoencoders with Swin Transformer.

Wang Qingbin, Xiong Yuxuan, Zhu Hanfeng, Mu Xuefeng, Zhang Yan, Ma Yutao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Cervical cancer poses a major health threat to women globally. Optical coherence tomography (OCT) imaging has recently shown promise for non-invasive cervical lesion diagnosis. However, obtaining high-quality labeled cervical OCT images is challenging and time-consuming as they must correspond precisely with pathological results. The scarcity of such high-quality labeled data hinders the application of supervised deep-learning models in practical clinical settings. This study addresses the above challenge by proposing CMSwin, a novel self-supervised learning (SSL) framework combining masked image modeling (MIM) with contrastive learning based on the Swin-Transformer architecture to utilize abundant unlabeled cervical OCT images.

METHODS

In this contrastive-MIM framework, mixed image encoding is combined with a latent contextual regressor to solve the inconsistency problem between pre-training and fine-tuning and separate the encoder's feature extraction task from the decoder's reconstruction task, allowing the encoder to extract better image representations. Besides, contrastive losses at the patch and image levels are elaborately designed to leverage massive unlabeled data.

RESULTS

We validated the superiority of CMSwin over the state-of-the-art SSL approaches with five-fold cross-validation on an OCT image dataset containing 1,452 patients from a multi-center clinical study in China, plus two external validation sets from top-ranked Chinese hospitals: the Huaxi dataset from the West China Hospital of Sichuan University and the Xiangya dataset from the Xiangya Second Hospital of Central South University. A human-machine comparison experiment on the Huaxi and Xiangya datasets for volume-level binary classification also indicates that CMSwin can match or exceed the average level of four skilled medical experts, especially in identifying high-risk cervical lesions.

CONCLUSION

Our work has great potential to assist gynecologists in intelligently interpreting cervical OCT images in clinical settings. Additionally, the integrated GradCAM module of CMSwin enables cervical lesion visualization and interpretation, providing good interpretability for gynecologists to diagnose cervical diseases efficiently.

Для цитирования: Wang Qingbin, Xiong Yuxuan, Zhu Hanfeng, Mu Xuefeng, Zhang Yan, Ma Yutao. Cervical OCT image classification using contrastive masked autoencoders with Swin Transformer.. Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society. 2024. DOI: 10.1016/j.compmedimag.2024.102469.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.