MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.placenta.2026.06.018

Медицинская библиотека · Placenta · 2026

Site-dependent differences in placental stiffness in extrachorial placenta: implications for shear wave elastography assessment.

Okuyama Ayumi, Goto Minako, Komase Nao, Seo Kohei, Koike Chihiro, Ichizuka Kiyotake

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Placental stiffness measured using shear wave elastography has been proposed as a potential indicator of placental structural characteristics. However, the measurement sites for placental stiffness have not yet been standardized. In this study, we aimed to compare the placental stiffness between extrachorial (circumvallate and circummarginate) and normal placentas to evaluate the impact of measurement site selection on the assessment.

METHODS

In this cross-sectional study of 169 singleton placentas (135 normal, 34 extrachorial) delivered after 32 weeks, the shear wave velocity (SWV) was measured at the placental marginal area and near the umbilical cord insertion site. A histopathological evaluation was performed in representative cases.

RESULTS

The median SWV at the marginal area was significantly higher in the extrachorial placenta group than in the normal placenta group (2.20 vs. 2.07 m/s, p < 0.01). By contrast, no significant difference was observed near the umbilical cord insertion site between the groups. Secondary analyses showed consistent findings for the circumvallate and circummarginate subtypes. The histopathological examination revealed marked fibrin deposition on the fetal side at the placental margin in extrachorial placentas, which may contribute to localized increases in placental stiffness.

DISCUSSION: These findings suggest that placental stiffness measurements may be influenced by the choice of measurement site, particularly in the presence of localized structural changes such as those observed in extrachorial placentas. Measurements near the umbilical cord insertion site may be less affected by marginal structural variations and may better reflect the overall mechanical properties of the placenta.

Для цитирования: Okuyama Ayumi, Goto Minako, Komase Nao, Seo Kohei, Koike Chihiro, Ichizuka Kiyotake. Site-dependent differences in placental stiffness in extrachorial placenta: implications for shear wave elastography assessment.. Placenta. 2026. DOI: 10.1016/j.placenta.2026.06.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.