Real-world integration of an autonomous artificial intelligence system for diabetic retinopathy screening in an endocrinology outpatient clinic.

Gil Or, Arad Amiram, Fogel Miri, Vorobichik-Berar Ofri, Katz Gabriel, Gurevich Rina, Tirosh Amir, Pelz-Sinvani Naama, Moroz Iris, Shalem Shiran, Siesky Brent A, Verticchio Vercellin Alice Chandra, Harris Alon, Cohen Gal Yaakov

СтатьяПеревод в очереди

Аннотация

AIM: To evaluate a real-world clinical integration of an autonomous artificial intelligence (AI) system (AEYE Diagnostic Screening (AEYE-DS), AEYE Health, USA) for diabetic retinopathy (DR) screening using the Topcon NW500 camera (Topcon, Japan) in an endocrinology clinic.

METHODS

Adults with type 1 or type 2 diabetes without previously reported DR attending routine endocrinology follow-up were invited to participate. Non-mydriatic, macula-centred fundus photographs were acquired by a novice, non-ophthalmic operator. Images were analysed by AEYE-DS to detect more-than-mild DR (mtmDR). AI-positive results prompted physician counselling and automated referral for internal confirmatory examination.

RESULTS

Definitive AEYE-DS results were obtained for 95.7% (245/256) of participants without pharmacological dilation. Seventy-six (29.6%) patients screened positive for mtmDR, of whom 34 (44.7%) completed confirmatory examination at the institution's retina clinic; externally completed follow-up was not captured. Four patients (11.8% of those evaluated) required treatment with intravitreal anti-vascular endothelial growth factor therapy or panretinal photocoagulation. Additional previously unrecognised ocular conditions were identified among several AI-positive patients. Patient satisfaction was high, with >80% reporting the screening was easy to use, time-efficient and recommendable.

CONCLUSIONS

In a real-world endocrinology clinic, autonomous AI screening for DR using AEYE-DS integrated with the Topcon NW500 enabled efficient DR screening and achieved high non-mydriatic imageability. A clinically relevant proportion of patients requiring ophthalmic evaluation has been captured. Internal referral for confirmatory testing enabled assessment of downstream outcomes. The findings support scalable, point-of-care autonomous screening and a stepped-referral approach for AI-positive patients.

Для цитирования: Gil Or, Arad Amiram, Fogel Miri, Vorobichik-Berar Ofri, Katz Gabriel, Gurevich Rina, Tirosh Amir, Pelz-Sinvani Naama, Moroz Iris, Shalem Shiran, Siesky Brent A, Verticchio Vercellin Alice Chandra, Harris Alon, Cohen Gal Yaakov. Real-world integration of an autonomous artificial intelligence system for diabetic retinopathy screening in an endocrinology outpatient clinic.. The British journal of ophthalmology. 2026. DOI: 10.1136/bjo-2025-328991.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.