Quantifying the Viscoelastic Properties of Pancreatic Tissue: A Comparative Study of Human, Porcine and Engineered Hydrogel.

Joshi Kunal, Espino Daniel M, Shepherd Duncan E T, Mahmoodi Nasim, Roberts Keith J, Chatzizacharias Nikolaos, Marudanayagam Ravi, Sutcliffe Robert P

СтатьяПеревод в очереди

Аннотация

Pancreatoduodenectomy (PD) is among the most complex abdominal procedures, with a leak from the pancreatic anastomosis (postoperative pancreatic fistula, POPF) continuing to be a major source of morbidity and mortality. The mechanical characteristics of the pancreas, particularly tissue texture, are closely linked to POPF risk, yet remain poorly defined, limiting the accuracy of currently available training models. This study sought to quantify the viscoelastic behaviour of human pancreatic tissue and to compare it with porcine pancreas and a commercially available synthetic substitute. Fresh and frozen human pancreatic samples, porcine lobes, and synthetic tissues underwent uniaxial compression ramp testing and dynamic mechanical analysis. Human pancreatic tissue was markedly 'stiffer' (mean Young's modulus 148.3 ± 117.0 kPa) compared with porcine (25.1 ± 17.1 kPa) and synthetic (34.5 ± 17.6 kPa) samples. Hard pancreas exhibited over twice the material stiffness of soft pancreas in both fresh (218.8 vs. 93.0 kPa, p < 0.001) and frozen (148.9 vs. 55.6 kPa, p = 0.002) states, whilst no significant variation was observed between different porcine lobes. Storage and loss modulus assessment demonstrated frequency-dependent differences, with synthetic models unable to reproduce the nonlinear viscoelastic profile of human tissue. These findings provide the first robust biomechanical benchmarks for pancreatic tissue and reveal the limitations of current phantoms. Integrating these data into advanced synthetic and computational models may improve surgical training, reduce the learning curve, and enhance patient outcomes after PD.

Для цитирования: Joshi Kunal, Espino Daniel M, Shepherd Duncan E T, Mahmoodi Nasim, Roberts Keith J, Chatzizacharias Nikolaos, Marudanayagam Ravi, Sutcliffe Robert P. Quantifying the Viscoelastic Properties of Pancreatic Tissue: A Comparative Study of Human, Porcine and Engineered Hydrogel.. Annals of biomedical engineering. 2026. DOI: 10.1007/s10439-026-04235-1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.