MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.meddos.2024.09.005

Медицинская библиотека · Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2024

Evaluation of dose and anatomy variability for nasopharyngeal carcinoma radiotherapy with a new fully integrated CT-linac.

Zhang Fan, Liu Jing, Zhou Mi, Li Xutong, Yue Lu, Zhao Chong, Qi Zhenyu, Deng Xiaowu, Peng Yinglin, Luo Zhiping

СтатьяПеревод в очереди

Аннотация

The goal of this study was to investigate the variability of target volume and parotid gland dose distribution for nasopharyngeal carcinoma (NPC), and to explore the shifting patterns of parotid gland centroid and neck radius during radiotherapy. Twenty patients with NPC were enrolled. The target volume dose difference between planning dose and recalculated dose on weekly CT was analyzed. The recalculated doses on every weekly CT were cumulated to assess the difference between delivered dose and planning dose. The relationship of parotid gland centroid deviation with dose was studied, and the shrinking distances of neck radius were calculated for cervical vertebra 1, 2, 3 levels (C1, C2, C3). The ratio of GTVs and CTVs doses on weekly CTs to the doses on planning CT was all above 0.98; the dose of PTVs on weekly CT tended to decrease compared with planning. RMD was defined as the ratio of the mean dose of the left and right parotid glands (L-PG, R-PG) to the planning mean dose. The fitted relationships of RMD and the deviation of centroid (D) for L-PG and R-PG were: RMD=0.37*D+0.98 (R2 = 0.62, p < 0.001) and RMD = 0.33*D+0.97 (R2 = 0.72, p < 0.001), respectively. The order of neck radius shrinking distance at different levels was C1>C2=C3. In this study, we quantitatively analyzed the dosimetric variabilities of target volumes, and established linear models of parotid gland dose and its centroid deviation, which provides fractional and full-course dose evaluation during radiotherapy for NPC.

Для цитирования: Zhang Fan, Liu Jing, Zhou Mi, Li Xutong, Yue Lu, Zhao Chong, Qi Zhenyu, Deng Xiaowu, Peng Yinglin, Luo Zhiping. Evaluation of dose and anatomy variability for nasopharyngeal carcinoma radiotherapy with a new fully integrated CT-linac.. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024. DOI: 10.1016/j.meddos.2024.09.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.