BACKGROUND

Endobronchial ultrasound (EBUS) with transbronchial needle aspiration increases the diagnostic yield of lung cancer staging. The left adrenal gland (LAG) is a common site for lung cancer metastasis. The modality of transesophageal examination with an EBUS bronchoscope (EUS-B) routinely for LAG has not been assessed.

OBJECTIVE

The aim of this study was to prospectively assess if evaluation and tissue sampling of the LAG could routinely be implemented in an EBUS procedure.

METHODS

Patients referred for EBUS between March and August 2017 had assessment of the LAG via EUS-B. Fine-needle aspiration (FNA) was performed in cases with a suspicious LAG. The detection rate, procedure time, and learning curve of four experienced EBUS-bronchoscopists was assessed, plus the diagnostic accuracy and complication rate of FNA.

RESULTS

In total, 313 consecutive patients were included. The overall LAG detection rate was 87.5%. After the initial learning curve, the detection rate for all four bronchoscopists was >93%. The detection rate did not correlate with any patient characteristics. EUS-B-FNA revealed nine LAG metastases, with a sensitivity, specificity, and accuracy of 75%, 100%, and 99%, respectively. The mean EUS-B operation time was 194.4 s, with 594.8 s for FNA. There were no FNA-associated complications.

CONCLUSIONS

Evaluation of the LAG with EUS-B could routinely be included in an EBUS procedure if necessary. A high detection rate can be achieved after an initial learning period. FNA of the LAG was feasible and safe. EUS-B of the LAG could be integrated into the usual EBUS/EUS-B procedure in lung cancer staging workup.

Для цитирования: Darwiche Kaid, Becker Jonathan, Winantea Jane, Karpf-Wissel Ruediger, Funke Faustina, Stenzel Elena, Hautzel Hubertus, Hager Thomas, Eisenmann Stephan. Integration of Bronchoscopic Transesophageal Ultrasound Examination of the Left Adrenal Gland into Routine Lung Cancer Staging Workup: A Prospective Trial.. Respiration; international review of thoracic diseases. 2019. DOI: 10.1159/000503396.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.