MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcs.70177

Медицинская библиотека · The international journal of medical robotics + computer assisted surgery : MRCAS · 2026

Portable Moxibustion Robot With Intelligent Acupoint Positioning Guided by Visual Sensing.

Wang Lanhui, Zhang Pengcheng, Wang Ziqi, Hao Mingrui, Deng Zhaokun, Guan Ling, Li Ying, Wang Taizhong, Guo Kairou, Wang Shuangyi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To overcome key challenges in traditional moxibustion, such as the shortage of skilled practitioners, time-consuming and labour-intensive procedures, this study developed an intelligent robotic system for automated acupoint positioning and moxibustion execution.

METHODS

The system established a standardised acupoint coordinate map utilising DensePose-based body normalisation and statistical modelling from 50 subjects. A hybrid serial-parallel robot design enabled large workspace and high precision for bedside application. Safety was ensured by a Model Predictive Controller utilising real-time thermal feedback for dynamic distance adjustment.

RESULTS

Experimental validation demonstrated precise spatial positioning, with mean errors of 5.8 ± 2.9 $5.8\pm 2.9$ mm (back), 6.4 ± 3.7 $6.4\pm 3.7$ mm (abdomen), 4.3 ± 2.7 $4.3\pm 2.7$ mm (upper limbs), and 9.4 ± 6.2 $9.4\pm 6.2$ mm (lower limbs). The system responded to temperature changes within 0.25 s, limiting overshoot to below 0.8°C.

CONCLUSIONS

This integrated robotic system provides a precise and scalable solution for automated moxibustion, particularly valuable for resource-limited clinical environments.

TRIAL REGISTRATION: It was an investigational clinical study, not a registrational clinical trial.

Для цитирования: Wang Lanhui, Zhang Pengcheng, Wang Ziqi, Hao Mingrui, Deng Zhaokun, Guan Ling, Li Ying, Wang Taizhong, Guo Kairou, Wang Shuangyi. Portable Moxibustion Robot With Intelligent Acupoint Positioning Guided by Visual Sensing.. The international journal of medical robotics + computer assisted surgery : MRCAS. 2026. DOI: 10.1002/rcs.70177.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.