OBJECTIVE

This study examined the biomechanical properties of computer-aided design/computer-aided manufacturing (CAD/CAM) retainers made of titanium and nickel-titanium (NiTi).

METHODS

Four retainer types were tested: (1) twisted steel, (2) NiTi, (3) cut titanium, and (4) printed titanium. Longitudinal wires were manufactured (2-4) and subjected to a three-point bending test (3PBT). In a biomechanical bending test (BMT), retainers were designed from patient scans and applied to models in an Orthodontic Measurement and Simulation System, with the maxillary central incisor and mandibular central incisor loaded with deflections of ±0.2 mm and rotation of ±1°.

RESULTS

The 3PBT showed that NiTi wires exhibited a characteristic hysteresis loop, whereas the cut and printed titanium wires had different flow and yield strengths. The BMT forces during intrusive and extrusive movements were measured, and the findings revealed that in the maxilla, all CAD/CAM materials showed significant differences from the twisted steel, with NiTi differing from the cut and printed titanium. In the mandible, the forces were generally higher, with significant differences observed at 0.1-mm extrusion and 0.2-mm deflection. In addition, significant differences were observed in the mesial and distal deflections, particularly in the mandible, where the cut titanium generated the lowest forces. Twisted steel exhibited the lowest torque, whereas cut titanium exhibited the highest torque.

CONCLUSIONS

CAD/CAM retainers differ significantly from conventional twisted steel retainers, with notable differences between NiTi and titanium retainers, especially in the maxilla. However, these differences may be negligible in the mandible due to the shorter interdental distance.

Для цитирования: Nottmeier Cita, Schwieder Talisa, Georgi Gina Marie, Schmid-Hermann Carmen, Kahl-Nieke Bärbel, Seiler Daniel, Bourauel Christoph, Koehne Till. Comparison of the biomechanical properties of CAD/CAM individualized lingual retainers: An in vitro study.. Korean journal of orthodontics. 2025. DOI: 10.4041/kjod25.114.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.