MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1098612x251398915

Медицинская библиотека · Journal of feline medicine and surgery · 2025

Comparison of thyrotropin concentrations measured by bulk acoustic wave technology and chemiluminescence in hyperthyroid cats and cats with non-thyroidal illness.

Brassard Camille, DeMonaco Stefanie M, Wilkinson Ashley R, Keebaugh Audrey E, Bolton Timothy A

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

ObjectivesA thyrotropin (also known as thyroid-stimulating hormone [TSH]) assay using bulk acoustic wave (TSH-BAW) technology is a sensitive and specific test for diagnosing hyperthyroidism; however, the effect of various types of non-thyroidal illness (NTI) have not been evaluated with this assay. The objectives of this study were to compare serum TSH concentrations using the TSH-BAW and a currently available TSH chemiluminescent immunoassay (TSH-CLIA) in hyperthyroid cats, cats with NTI and healthy cats, as well as to compare sensitivity and specificity for diagnosing hyperthyroidism.MethodsA prospective cross-sectional study was conducted comparing the TSH concentration of 37 hyperthyroid, 32 healthy and 32 NTI cats using the TSH-CLIA and TSH-BAW assays. The effect of disease severity was evaluated with hyperthyroidism and NTI.ResultsThe TSH-BAW had a lower sensitivity (78%, 95% confidence interval [CI] 62-90) and negative predictive value (89%, 95% CI 79-95) but higher specificity (97%, 95% CI 89-100) and positive predictive value (94%, 95% CI 79-99) than the TSH-CLIA. The median serum TSH concentration was significantly different between hyperthyroid cats and both healthy and NTI cats with both assays (P <0.01) but was not different between NTI and healthy cats (TSH-CLIA P = 0.168, TSH-BAW P = 0.673). Eight (21.6%) hyperthyroid cats had a detectable TSH-BAW but undetectable TSH-CLIA concentration, with seven (18.9%) having a TSH-BAW within the reference interval. A total of 12 (18.8%) non-hyperthyroid cats (four [12.5%] healthy cats and eight [25%] NTI cats) had an undetectable TSH-CLIA compared with only two (6%) cats (one [3%] healthy cat and one [3%] NTI cat) with the TSH-BAW assay. The proportion of cats with an undetectable serum TSH concentration was significantly higher with the TSH-CLIA than the TSH-BAW in NTI cats (P = 0.008). This was especially evident in NTI cats suffering from moderate to severe illnesses (P = 0.025).Conclusions and relevanceThe TSH-BAW has a high specificity for detecting hyperthyroidism and identifies a normal serum TSH concentration in non-hyperthyroid cats more often than the TSH-CLIA. However, a normal result cannot be used to rule out hyperthyroidism.

Для цитирования: Brassard Camille, DeMonaco Stefanie M, Wilkinson Ashley R, Keebaugh Audrey E, Bolton Timothy A. Comparison of thyrotropin concentrations measured by bulk acoustic wave technology and chemiluminescence in hyperthyroid cats and cats with non-thyroidal illness.. Journal of feline medicine and surgery. 2025. DOI: 10.1177/1098612x251398915.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.