In vivo ureteroscopic intrarenal pressures and clinical outcomes: a multi-institutional analysis of 120 consecutive patients.

Croghan Stefanie M, Cunnane Eoghan M, O'Meara Sorcha, Muheilan Muheilan, Cunnane Connor V, Patterson Kenneth, Skolarikos Andreas, Somani Bhaskar, Jack Gregory S, Forde James C, O'Brien Fergal J, Walsh Michael T, Manecksha Rustom P, McGuire Barry B, Davis Niall F

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the pressure range generated in the human renal collecting system during ureteroscopy (URS), in a large patient sample, and to investigate a relationship between intrarenal pressure (IRP) and outcome.

PATIENTS AND

METHODS

A prospective multi-institutional study was conducted, with ethics board approval; February 2022-March 2023. Recruitment was of 120 consecutive consenting adult patients undergoing semi-rigid URS and/or flexible ureterorenoscopy (FURS) for urolithiasis or diagnostic purposes. Retrograde, fluoroscopy-guided insertion of a 0.036-cm (0.014″) pressure guidewire (COMET™ II, Boston Scientific, Marlborough, MA, USA) to the renal pelvis was performed. Baseline and continuous ureteroscopic IRP was recorded, alongside relevant operative variables. A 30-day follow-up was completed. Descriptive statistics were applied to IRP traces, with mean (sd) and maximum values and variance reported. Relationships between IRP and technical variables, and IRP and clinical outcome were interrogated using the chi-square test and independent samples t-test.

RESULTS

A total of 430 pressure traces were analysed from 120 patient episodes. The mean (sd) baseline IRP was 16.45 (5.99) mmHg and the intraoperative IRP varied by technique. The mean (sd) IRP during semi-rigid URS with gravity irrigation was 34.93 (11.66) mmHg. FURS resulted in variable IRP values: from a mean (sd) of 26.78 (5.84) mmHg (gravity irrigation; 12/14-F ureteric access sheath [UAS]) to 87.27 (66.85) mmHg (200 mmHg pressurised-bag irrigation; 11/13-F UAS). The highest single pressure peak was 334.2 mmHg, during retrograde pyelography. Six patients (5%) developed postoperative urosepsis; these patients had significantly higher IRPs during FURS (mean [sd] 81.7 [49.52] mmHg) than controls (38.53 [22.6] mmHg; P < 0.001).

CONCLUSIONS

A dynamic IRP profile is observed during human in vivo URS, with IRP frequently exceeding expected thresholds. A relationship appears to exist between elevated IRP and postoperative urosepsis.

Для цитирования: Croghan Stefanie M, Cunnane Eoghan M, O'Meara Sorcha, Muheilan Muheilan, Cunnane Connor V, Patterson Kenneth, Skolarikos Andreas, Somani Bhaskar, Jack Gregory S, Forde James C, O'Brien Fergal J, Walsh Michael T, Manecksha Rustom P, McGuire Barry B, Davis Niall F. In vivo ureteroscopic intrarenal pressures and clinical outcomes: a multi-institutional analysis of 120 consecutive patients.. BJU international. 2023. DOI: 10.1111/bju.16169.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.