MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10895-023-03395-w

Медицинская библиотека · Journal of fluorescence · 2024

Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay.

Zhong Shuhai, Liang Huankun, Peng Fenglan, Lu Yanhong, Liu Tiancai, Kulchytski Uladzimir, Dong Wenqi

СтатьяПеревод в очереди

Аннотация

Prolactin (PRL) and growth hormone (GH) are two important hormones secreted by the pituitary gland, and their abnormal levels are often related to disease status. This study aimed to establish a new dual-label time-resolved fluorescence immunoassay (TRFIA) to quantitatively measure PRL and GH levels in serum. A sandwich TRFIA was optimized and established: anti-PRL/GH antibodies immobilized on 96-well plates captured PRL/GH and then banded together with anti-PRL/GH paired antibodies labeled with europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally, a time-resolved analyzer measured the Eu3+/Sm3+ fluorescence values. Clinical serum samples were used to evaluate the detection performance of this method. The sensitivities of this dual-label TRFIA were 0.35 ng/mL and 0.45 ng/mL, respectively, and the detection range was between 0.1 and 1000 ng/mL. All the cross-reactivities were lower than 1.07%. The intra-assay and interassay coefficients of variation were 2.18-7.85% and 2.25-7.30%, respectively. Compared with the registered TRFIA kits, a high Pearson coefficient (r = 0.9626 and 0.9675) was observed. This dual-label TRFIA has high sensitivity, accuracy and specificity with good clinical detection performance, representing a suitable alternative to existing methods for determining PRL and GH levels, and is expected to be used in the clinic in the future.

Для цитирования: Zhong Shuhai, Liang Huankun, Peng Fenglan, Lu Yanhong, Liu Tiancai, Kulchytski Uladzimir, Dong Wenqi. Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay.. Journal of fluorescence. 2024. DOI: 10.1007/s10895-023-03395-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.