MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm15051865

Медицинская библиотека · Journal of clinical medicine · 2026

Three-Dimensional Postmortem Ultrasound of the Fetal Corneal Volume to Estimate Postmortem Interval.

Ibarra Vilar Patricia, Badr Dominique A, De Luca Laura, Cos Sanchez Teresa, Jani Jacques C, Kang Xin

СтатьяПеревод в очереди

Аннотация

Objectives

To develop and prospectively validate a predictive model to estimate the fetal postmortem interval (PMI) using three-dimensional postmortem ultrasound (3D PM-US) measurements of corneal and ocular volumes.

Methods

Single-center study including fetuses ≥ 20 weeks' gestation with known time of death after feticide. A retrospective training cohort (n = 63; November 2022-July 2023) and a prospective validation cohort (n = 28; February-August 2025) were used. Corneal and ocular volumes were measured using the VOCAL™ rotation multiplanar technique; the cornea-to-eyeball volume ratio was calculated for each case. Automated machine learning (AutoML) was used to develop and validate a gradient boosting machine (GBM) model. Model performance was evaluated using the root mean squared error (RMSE), mean absolute error (MAE), and coefficient of determination (R2).

Results

Ninety-four fetuses were included; three were excluded (two for extreme death-US intervals of 165 and 166 h; one for open eyelids). Median gestational age was 29.3 weeks (IQR 27.2-32.9); median birthweight was 1325 g (IQR 980-1880). The cornea-to-eyeball volume ratio was an independent predictor of PMI (p < 0.001). The GBM model explained 91% of the variance in the training cohort (R2 = 0.91, RMSE = 11.49 h, MAE = 8.45 h) and 75% in the validation cohort (R2 = 0.75, RMSE = 18.32 h, MAE = 14.49 h), demonstrating strong predictive accuracy and minimal overfitting. Variable importance analysis confirmed the cornea-to-eyeball ratio as the most influential and biologically plausible predictor of PMI. A Shiny web application was developed to facilitate clinical implementation.

Conclusions

3D PM-US measurements of the fetal cornea and eyeball can reliably and quantitatively estimate the PMI with good predictive accuracy using a GBM model. Multicenter studies are required to further refine the model, enable external validation, and determine its clinical and forensic utility.

Для цитирования: Ibarra Vilar Patricia, Badr Dominique A, De Luca Laura, Cos Sanchez Teresa, Jani Jacques C, Kang Xin. Three-Dimensional Postmortem Ultrasound of the Fetal Corneal Volume to Estimate Postmortem Interval.. Journal of clinical medicine. 2026. DOI: 10.3390/jcm15051865.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.