MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-04248-1

Медицинская библиотека · Scientific reports · 2025

Experimental and CFD analysis of flow impediments and encrustation in ureteral stents using in vitro urinary tract model.

Islam Md Didarul, Kang Hyo Jeong, Tae Sung Jin, Kim Kyung-Wuk, Choi Young Ho, Lee Seung Bae, Rakibuzzaman Md, Kim Min Uk, Kim Hyoung-Ho

СтатьяПеревод в очереди

Аннотация

A significant challenge for urological treatment is caused by encrustation that can obstruct urinary drainage. We analyzed the rate of encrustation formation for the initial three weeks in Conventional Double J Stent (CDJS), Renovated Double J Stent (RDJS), and Single J Stent (SJS) under patient-specific control conditions (37 °C, pH 7.8, 60 mL/hr., 50% stenosis). A conceptually designed in vitro urinary tract model representing the kidney, ureter and bladder model is used where the inlet flow rate is controlled with a peristaltic pump, and when the bladder is filled with artificial urine (AU), it is emptied manually, and the time is measured to calculate flow impediments. Stents have been removed from the tract after 21 days to measure mass and scanning electron microscope (SEM) analysis. A Computational Fluid Dynamics (CFD) analysis has been done to show the velocity profile and wall shear stress (WSS) of stents. RDJS has shown the highest flow rate and stable flow performance from the experiment, and SJS exhibited the lowest encrustation with a mass increase of 0.025 g compared to RDJS (0.053 g) and CDJS (0.057 g). The SEM image showed encrustation covered 10.37% of the SJS significantly lower than RDJS (13.04%) and CDJS (13.52%) near the stenosis side holes. The research evidence on SJS demonstrates the least encrustation of SJS stenosis region is further validated through the simulation result which showed a higher wall shear stress (10.4 mPa) for SJS at that location. SJS should be used for short durations for high-risk patients and RDJS for better flow maintenance, which indicates that stent selection should focus on improving the patient's outcomes.

Для цитирования: Islam Md Didarul, Kang Hyo Jeong, Tae Sung Jin, Kim Kyung-Wuk, Choi Young Ho, Lee Seung Bae, Rakibuzzaman Md, Kim Min Uk, Kim Hyoung-Ho. Experimental and CFD analysis of flow impediments and encrustation in ureteral stents using in vitro urinary tract model.. Scientific reports. 2025. DOI: 10.1038/s41598-025-04248-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.