MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13014-024-02411-y

Медицинская библиотека · Radiation oncology (London, England) · 2024

A 4D-CBCT correction network based on contrastive learning for dose calculation in lung cancer.

Cao Nannan, Wang Ziyi, Ding Jiangyi, Zhang Heng, Zhang Sai, Gao Liugang, Sun Jiawei, Xie Kai, Ni Xinye

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to present a deep-learning network called contrastive learning-based cycle generative adversarial networks (CLCGAN) to mitigate streak artifacts and correct the CT value in four-dimensional cone beam computed tomography (4D-CBCT) for dose calculation in lung cancer patients.

METHODS

4D-CBCT and 4D computed tomography (CT) of 20 patients with locally advanced non-small cell lung cancer were used to paired train the deep-learning model. The lung tumors were located in the right upper lobe, right lower lobe, left upper lobe, and left lower lobe, or in the mediastinum. Additionally, five patients to create 4D synthetic computed tomography (sCT) for test. Using the 4D-CT as the ground truth, the quality of the 4D-sCT images was evaluated by quantitative and qualitative assessment methods. The correction of CT values was evaluated holistically and locally. To further validate the accuracy of the dose calculations, we compared the dose distributions and calculations of 4D-CBCT and 4D-sCT with those of 4D-CT.

RESULTS

The structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) of the 4D-sCT increased from 87% and 22.31 dB to 98% and 29.15 dB, respectively. Compared with cycle consistent generative adversarial networks, CLCGAN enhanced SSIM and PSNR by 1.1% (p < 0.01) and 0.42% (p < 0.01). Furthermore, CLCGAN significantly decreased the absolute mean differences of CT value in lungs, bones, and soft tissues. The dose calculation results revealed a significant improvement in 4D-sCT compared to 4D-CBCT. CLCGAN was the most accurate in dose calculations for left lung (V5Gy), right lung (V5Gy), right lung (V20Gy), PTV (D98%), and spinal cord (D2%), with the relative dose difference were reduced by 6.84%, 3.84%, 1.46%, 0.86%, 3.32% compared to 4D-CBCT.

CONCLUSIONS

Based on the satisfactory results obtained in terms of image quality, CT value measurement, it can be concluded that CLCGAN-based corrected 4D-CBCT can be utilized for dose calculation in lung cancer.

Для цитирования: Cao Nannan, Wang Ziyi, Ding Jiangyi, Zhang Heng, Zhang Sai, Gao Liugang, Sun Jiawei, Xie Kai, Ni Xinye. A 4D-CBCT correction network based on contrastive learning for dose calculation in lung cancer.. Radiation oncology (London, England). 2024. DOI: 10.1186/s13014-024-02411-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.