m+Medelevator.RU
← Поиск публикаций
Analytica chimica acta · 2026

Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sanli Cansu, Isa Ahmed, Cetinkaya Ahmet, Gurbuz Havva Nur, Sorkhe Yahya, Unal M Altay, Uzunoglu Aytekin, Atici Esen Bellur, Ozkan Sibel A

Аннотация

BACKGROUND: Pomalidomide (POM), a third-generation immunomodulatory drug, is widely used in the therapeutic regimen of multiple myeloma and other hematologic malignancies. Owing to its narrow therapeutic index and substantial interindividual pharmacokinetic variability, accurate quantification of POM in biological matrices is essential to optimize dosing regimens and minimize adverse effects. Conventional analytical systems like HPLC and LC-MS/MS, while highly accurate, can be time-consuming, costly, and technically demanding.

RESULTS: This study covers the design of a molecularly imprinted polymer (MIP)-based electrochemical sensor incorporating two-dimensional Ti3C2TX MXene nanaolayers (Ti3C2Tx NLs) for sensitive and selective detection and quantification of POM. The sensor's performance was enhanced by the integration of Ti3C2Tx NLs, followed by modifying a GCE via electropolymerization of its surface with 3-thienylboronic acid (3-TBA) as the functional monomer and aniline (ANI) as a co-monomer. Critical parameters, including the template: monomer ratio, the number of polymerization cycles, and the rebinding time, were systematically optimized. EIS, CV, and SEM analyses were used to confirm the formation of selective recognition cavities and the sensor's electrochemical functionality. The developed MIP sensor exhibited excellent linearity across a concentration range of 1.75 × 10-13 M to 1.00 × 10-12 M. It demonstrated outstanding selectivity for POM, even in the presence of structurally similar analogues, co-administered drugs, common biomolecules, and frequently encountered inorganic ions.

SIGNIFICANCE AND NOVELTY: Overall, this highly sensitive, selective, and cost-effective MIP-based sensor, which demonstrates excellent stability and performance even in complex matrices, provides a robust, practical analytical tool for routine therapeutic drug monitoring of POM in clinical settings. Moreover, the sensor's straightforward fabrication, low operational cost, and reproducible analytical behavior make it a promising alternative to conventional methods, ultimately contributing to more efficient, accessible, and patient-centered therapeutic monitoring platforms.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты