MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Journal of Ayub Medical College, Abbottabad : JAMC · 2004

Maternal blood loss by expansion of uterine incision at caesarean section--a comparison between sharp and blunt techniques.

Hameed Nazli, Ali Mohammad Asghar

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

In order to minimize intra operative blood loss during caesarean section, two techniques of expansion of uterine incision (sharp versus blunt) while performing lower segment transverse caesareans deliveries and their effect upon intraoperative blood loss were studied. Moreover, each method was also compared for its inadvertent extension of uterine incision laterally or into the broad ligament, into the cervix or vagina.

METHOD: A quasi-experimental study with convenient sampling, involving two groups of women who underwent lower transverse segment Cesarean section. Both groups were studied for their demographic characteristics and clinical data. Standard surgical techniques were used in both groups except the expansion of uterine incision, either by sharp or blunt methods. Finally a comparison of two groups was made regarding blood loss, change in haematocrit, blood transfusion and uterine tears. The study was conducted at Combined Military Hospital Rawalpindi during May 2002 to April 2003.

RESULTS

No significant difference was found between the two groups regarding their demographic characteristics and clinical data. Intraoperative blood loss and post-operative hematocrit drop were more significant in the patient group in which a blunt uterine incision was made. Besides, more patients in this group received blood transfusions. Unintended extension of uterine (tears) was also significantly higher in this group.

CONCLUSION

Sharp expansion of uterine incision during low segment caesarean section is safer and precise based on these results.

Для цитирования: Hameed Nazli, Ali Mohammad Asghar. Maternal blood loss by expansion of uterine incision at caesarean section--a comparison between sharp and blunt techniques.. Journal of Ayub Medical College, Abbottabad : JAMC. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.