La Radiologia medica · 2010
Magnetic resonance cholangiopancreatography and contrast-enhanced magnetic resonance cholangiopancreatography versus endoscopic ultrasonography in the diagnosis of extrahepatic biliary pathology.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Palmucci S, Mauro L A, La Scola S, Incarbone S, Bonanno G, Milone P, Russo A, Ettorre G C
Аннотация
PURPOSE: This study compared the diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasonography (EUS) in evaluating the cause of extrahepatic bile duct dilatation.
MATERIALS AND METHODS: Forty-five patients (26 men, mean age 57 years) with extrahepatic biliary dilatation, as shown by transabdominal ultrasound, with or without elevated biliary and pancreatic serum indices, were prospectively studied with MRCP and EUS between September 2007 and October 2008. EUS and MRCP were performed within no more than 24 h of each other to reduce the possibility of changes due to stone migration. Image analysis was carried out in a double-blind fashion.
RESULTS: MRCP had 88.9% diagnostic accuracy, 91.9% sensitivity and 75% specificity, with 94.4% positive predictive value and 66.7% negative predictive value. EUS had 93.3% diagnostic accuracy, 97.3% sensitivity and 75% specificity; the positive and negative predictive values were 94.7% and 85.7%, respectively.
CONCLUSIONS: MRCP and EUS do not show significant statistical differences in diagnostic accuracy. MRCP is an accurate, noninvasive modality in the study of extrahepatic biliary pathology. EUS is especially reliable in patients with extrahepatic biliary obstruction caused by endoluminal sludge.
MATERIALS AND METHODS: Forty-five patients (26 men, mean age 57 years) with extrahepatic biliary dilatation, as shown by transabdominal ultrasound, with or without elevated biliary and pancreatic serum indices, were prospectively studied with MRCP and EUS between September 2007 and October 2008. EUS and MRCP were performed within no more than 24 h of each other to reduce the possibility of changes due to stone migration. Image analysis was carried out in a double-blind fashion.
RESULTS: MRCP had 88.9% diagnostic accuracy, 91.9% sensitivity and 75% specificity, with 94.4% positive predictive value and 66.7% negative predictive value. EUS had 93.3% diagnostic accuracy, 97.3% sensitivity and 75% specificity; the positive and negative predictive values were 94.7% and 85.7%, respectively.
CONCLUSIONS: MRCP and EUS do not show significant statistical differences in diagnostic accuracy. MRCP is an accurate, noninvasive modality in the study of extrahepatic biliary pathology. EUS is especially reliable in patients with extrahepatic biliary obstruction caused by endoluminal sludge.
Предметные рубрики MeSH
Bile Ducts, ExtrahepaticCholangiopancreatography, Magnetic ResonanceCholestasis, ExtrahepaticContrast MediaDilatation, PathologicEndosonographyFemaleHumansImage Interpretation, Computer-AssistedMaleMeglumineMiddle AgedOrganometallic CompoundsPredictive Value of TestsProspective StudiesSensitivity and Specificity