DOI 10.1016/j.arth.2026.04.110
Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty.
Аннотация
BACKGROUND
Fluoroscopic-assisted computer navigation is widely used to guide intraoperative decisions on leg length (LL) and offset in primary total hip arthroplasty (THA), but its accuracy remains under-evaluated. This study assessed the precision of a fluoroscopy-based navigation system by comparing its intraoperative predictions to validated postoperative measurements.
METHODS
We retrospectively reviewed 490 consecutive primary THA cases performed by three surgeons at a tertiary academic center. Intraoperative changes in LL and offset using a fluoroscopic navigation system were recorded. Pre- and postoperative antero-posterior pelvis radiographs were measured using an artificial intelligence (AI)-based algorithm to determine actual changes in LL and offset. Navigated and radiographic values were compared using mean/median differences and by percentage of cases within clinically relevant thresholds: ± three, ± five, and ± 10 mm.
RESULTS
For LL, postoperative AI-based measurements showed a mean change of 4.1 ± 5.6 mm (median 3.7), while the intraoperative navigation system predicted a mean change of 2.5 ± 3.1 mm (median 2, P < 0.0001). Navigation underestimated LL change on average. Predictions were within ± three mm in 65.8% of cases, ± five mm in 86.0%, and ± 10 mm in 98.5%. For femoral offset, AI-based measurements showed a mean postoperative change of 1.7 ± 5.4 mm (median 1.6), compared with a mean predicted change of 3.4 ± 5.0 mm (median 3) from navigation (P < 0.0001). Navigation overestimated offset change on average. Accuracy was within ± three mm in 44.1% of cases, ± five mm in 64.9%, and ± 10 mm in 93.9%.
CONCLUSIONS
Although the fluoroscopy-based navigation system showed statistically significant differences from postoperative radiographic measurements, it achieved clinically acceptable accuracy in most cases. These findings support the system's utility in guiding THA while emphasizing the importance of intraoperative awareness of its limitations.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.