MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2026.101045

Медицинская библиотека · Physics and imaging in radiation oncology · 2026

Impact of dose calculation algorithm on magnetic resonance imaging-only radiotherapy for prostate and glioma.

Af Wetterstedt Sacha, Persson Emilia, Gustafsson Christian Jamtheim, Gunnlaugsson Adalsteinn, Lerner Minna, Olsson Lars E, Pommer Tobias

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Synthetic computed tomography (sCT) enables magnetic resonance imaging (MRI)-only radiotherapy by providing electron density information for dose calculation. While sCT-based planning has been proven sufficiently accurate for convolution-based dose calculation algorithms, linear Boltzmann transport equation (LBTE)-based approaches exhibit higher sensitivity to tissue heterogeneities. This study evaluated the accuracy of both dose calculation algorithm types for MRI-only in prostate and glioma radiotherapy.

MATERIALS AND

METHODS

Clinical treatment plans for thirty-nine prostate cancer patients and seventeen glioma patients were recalculated on atlas- and deep learning (DL)-based sCTs and conventional CT using convolution- and LBTE-based algorithms. Target dose metrics were analyzed as relative differences, while organs of interest (OOI) dose criteria were evaluated as absolute differences between sCT- and CT-based calculations. Statistical significance was assessed using paired t-tests (α = 0.05).

RESULTS

For target volumes, statistically significant differences between sCT- and CT-based calculations were observed for both dose calculation algorithms (p < 0.001). In prostate patients, mean differences in target dose metrics were ≤ 1.4% for the LBTE-based algorithm and ≤ 0.5% for the convolution-based algorithm. Slightly smaller dose differences were observed for glioma patients, ≤ 0.8% and ≤ 0.5%, respectively. OOI dose differences were small (≤ 0.6%). The LBTE-based algorithm consistently yielded the largest dose differences between CT and sCT.

CONCLUSIONS

Although the LBTE-based approach demonstrated higher sensitivity to sCT-related CT number discrepancies than the convolution-based dose calculation algorithm, the resulting dose differences remained within clinically acceptable limits, supporting the robustness of MRI-only radiotherapy for both atlas- and DL-based sCTs.

Для цитирования: Af Wetterstedt Sacha, Persson Emilia, Gustafsson Christian Jamtheim, Gunnlaugsson Adalsteinn, Lerner Minna, Olsson Lars E, Pommer Tobias. Impact of dose calculation algorithm on magnetic resonance imaging-only radiotherapy for prostate and glioma.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.101045.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.