MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcimb.2012.00071

Медицинская библиотека · Frontiers in cellular and infection microbiology · 2012

Achieving consistent multiple daily low-dose Bacillus anthracis spore inhalation exposures in the rabbit model.

Barnewall Roy E, Comer Jason E, Miller Brian D, Gutting Bradford W, Wolfe Daniel N, Director-Myska Alison E, Nichols Tonya L, Taft Sarah C

СтатьяПеревод в очереди

Аннотация

Repeated low-level exposures to biological agents could occur before or after the remediation of an environmental release. This is especially true for persistent agents such as B. anthracis spores, the causative agent of anthrax. Studies were conducted to examine aerosol methods needed for consistent daily low aerosol concentrations to deliver a low-dose (less than 10(6) colony forming units (CFU) of B. anthracis spores) and included a pilot feasibility characterization study, acute exposure study, and a multiple 15 day exposure study. This manuscript focuses on the state-of-the-science aerosol methodologies used to generate and aerosolize consistent daily low aerosol concentrations and resultant low inhalation doses to rabbits. The pilot feasibility characterization study determined that the aerosol system was consistent and capable of producing very low aerosol concentrations. In the acute, single day exposure experiment, targeted inhaled doses of 1 × 10(2), 1 × 10(3), 1 × 10(4), and 1 × 10(5) CFU were used. In the multiple daily exposure experiment, rabbits were exposed multiple days to targeted inhaled doses of 1 × 10(2), 1 × 10(3), and 1 × 10(4) CFU. In all studies, targeted inhaled doses remained consistent from rabbit-to-rabbit and day-to-day. The aerosol system produced aerosolized spores within the optimal mass median aerodynamic diameter particle size range to reach deep lung alveoli. Consistency of the inhaled dose was aided by monitoring and recording respiratory parameters during the exposure with real-time plethysmography. Overall, the presented results show that the animal aerosol system was stable and highly reproducible between different studies and over multiple exposure days.

Для цитирования: Barnewall Roy E, Comer Jason E, Miller Brian D, Gutting Bradford W, Wolfe Daniel N, Director-Myska Alison E, Nichols Tonya L, Taft Sarah C. Achieving consistent multiple daily low-dose Bacillus anthracis spore inhalation exposures in the rabbit model.. Frontiers in cellular and infection microbiology. 2012. DOI: 10.3389/fcimb.2012.00071.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.