Predicting Small Effective Optical Zone After SMILE via Multimodal Machine Learning Integrating Corneal Topography and Clinical Parameters.

Xiong Jian, Gao Weihao, Huang Fei, Ling Ling, Ai Chong, Zhang Xian, Cen Gao, Dai Dongrong, Li Wensheng, Ma Lan, Gui Fu

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To develop and validate a machine learning system for the preoperative prediction of small effective optical zone (EOZ; diameter < 5.5 mm) after small incision lenticule extraction (SMILE).

METHODS

In this multicenter cohort study, 1030 multimodal combinations of preoperative parameters (PP), anterior corneal curvature maps (AACM), surgery video frames, and three-month postoperative EOZ diameter from 1030 eyes (634 patients) undergoing SMILE were divided: 677 for training, 85 for primary validation, 85 for internal test, and 183 for external test. The AACM-PP-Model integrating AACM and PP was developed and compared against parameter-only or image-only models, with primary performance evaluated by the area under the receiver operating characteristic curve (AUROC) and macro F1 score.

RESULTS

In the primary validation set, the AACM-PP-Model achieved an AUROC of 0.897 (95% confidence interval [CI], 0.819-0.975) and macro F1 of 0.823. It outperformed the best parameter-only model (PP-CatBoost, AUROC of 0.885 [95% CI, 0.813-0.957], macro F1 of 0.821) and best image-only model (model based on suction-initiated, centering-checked frames and anterior axial curvature map [SIF-CCF-AACM-Model], AUROC of 0.837 [95% CI, 0.745-0.928], macro F1 of 0.612). Superiority of AACM-PP-Model over PP-CatBoost and SIF-CCF-AACM-Model was maintained in internal (AUROC 0.957 vs. 0.915 vs. 0.773) and external (0.863 vs. 0.814 vs. 0.660) test sets. Intraoperative frame models performed poorly (AUROC < 0.7 on all test sets).

CONCLUSIONS

Multimodal machine learning using standard preoperative data can accurately predict small post-SMILE EOZ, demonstrating superior generalization to support preoperative decision-making.

TRANSLATIONAL RELEVANCE: Objective preoperative risk stratification could aid in personalized surgical planning and help manage patient expectations regarding postoperative visual quality.

Для цитирования: Xiong Jian, Gao Weihao, Huang Fei, Ling Ling, Ai Chong, Zhang Xian, Cen Gao, Dai Dongrong, Li Wensheng, Ma Lan, Gui Fu. Predicting Small Effective Optical Zone After SMILE via Multimodal Machine Learning Integrating Corneal Topography and Clinical Parameters.. Translational vision science & technology. 2026. DOI: 10.1167/tvst.15.2.26.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.