Impact of Intraoperative Patient-Specific 3D-Printed Temporal Bones: A Randomized Controlled Trial.

Omari Adam, Nwosu Obinna I, Andersen Steven A W, Quesnel Alicia M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine if intraoperative inspection of patient-specific 3D-printed TB models, as a supplement to standard imaging, affects the cognitive load of surgeons during cochlear implantation (CI).

METHODS

This randomized controlled trial included 40 consecutive adult primary CI surgeries performed by seven attending and five trainee surgeons at a large CI center. Cases were randomized 1:1 to current standard with surgical planning based on imaging review (controls) or to current standard plus intra-operative inspection of a 3D-printed model (intervention). The primary outcome, intraoperative cognitive load, was measured using the Surgery Task Load Index (Surg-TLX) and analyzed with linear mixed-effects models. Secondary outcomes included ratings of model anatomy, utility, and user experience (Schlegel-questionnaire) and prediction of intraoperative challenges.

RESULTS

Attending surgeons experienced lower overall cognitive load using 3D models versus controls (3.8 vs. 5.5; p < 0.01), driven by reduced physical fatigue (p = 0.01). Conversely, residents reported higher overall load (7.2 vs. 4.8; p = 0.02) with increased mental (p = 0.01) and physical fatigue (p < 0.001). Fellows showed no significant difference in overall load (8.2 vs. 8.0; p = 0.88) but noted lower case complexity (p = 0.02) offset by higher physical fatigue (p = 0.04). Models were viewed as accurate and useful, particularly for trainee education, anticipating case difficulty and anatomical boundaries.

CONCLUSION

The clinical impact of intraoperative 3D-printed models during CI is modulated by surgical experience. For attendings, models act as high-fidelity references facilitating cognitive offloading, whereas they stimulate mental effort for trainees. Selective implementation is recommended to align use of models to surgical experience level to promote operative efficiency and surgical training.

LEVEL OF EVIDENCE: Level II.

Для цитирования: Omari Adam, Nwosu Obinna I, Andersen Steven A W, Quesnel Alicia M. Impact of Intraoperative Patient-Specific 3D-Printed Temporal Bones: A Randomized Controlled Trial.. The Laryngoscope. 2026. DOI: 10.1002/lary.70887.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.