MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrtlng.2026.102956

Медицинская библиотека · Heart & lung : the journal of critical care · 2026

Large language models fail to reliably predict emergent catheterization laboratory activation from prehospital electrocardiograms.

Legendre Emile, Cvek Urska, Greathouse Stewart, Toups Colton, Watkins Brandon, Jones Dillon, Janese David

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Rapid and accurate electrocardiogram (ECG) interpretation is essential for timely identification of ST-elevation myocardial infarction (STEMI) and activation of reperfusion pathways in emergency care.

OBJECTIVES

To evaluate the diagnostic performance of multimodal LLMs in identifying prehospital ECGs warranting emergent catheterization laboratory activation.

METHODS

We performed a retrospective analysis of 615 ECGs from 270 emergency medical service patient encounters (EMS) with concern for acute myocardial infarction. The reference standard was cardiology activation of the STEMI pathway for emergent angiography. LLM-based image interpretation (three models) and ECG machine algorithm interpretations were compared. Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy were calculated.

RESULTS

Gemini demonstrated the highest sensitivity (95.3%; 95% CI 91.7-97.3) but extremely poor specificity (9.4%), indicating a high false-positive rate. ChatGPT and Claude showed moderate sensitivity (68.1% and 67.2%) with limited specificity (42.3% and 46.5%). The ECG machine algorithm demonstrated more balanced performance, with sensitivity of 67.7% (95% CI 61.4-73.4) and higher specificity (64.2%) than all LLMs.

CONCLUSIONS

Multimodal LLM interpretation of prehospital ECGs demonstrated clinically unreliable performance for identifying ECGs warranting emergent cardiac catheterization laboratory activation when benchmarked against real-world cardiology activation decisions. Although some models achieved high sensitivity, poor specificity resulted in excessive false-positive activation recommendations. These findings suggest that general-purpose LLMs are not appropriate for ECG-based catheterization laboratory activation decisions in time-sensitive cardiopulmonary care workflows.

Для цитирования: Legendre Emile, Cvek Urska, Greathouse Stewart, Toups Colton, Watkins Brandon, Jones Dillon, Janese David. Large language models fail to reliably predict emergent catheterization laboratory activation from prehospital electrocardiograms.. Heart & lung : the journal of critical care. 2026. DOI: 10.1016/j.hrtlng.2026.102956.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.