MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11695-025-08446-8

Медицинская библиотека · Obesity surgery · 2026

Small Intestine Length Measurement Using 3D CT Volumetry and in Vivo Laparoscopic Measurement Using Pre-marked Graspers: A Comparative Study.

Abdelsalam Ahmed, Ghobashy Ahmed, Abdellatif Ahmed, Elholiby Tamer, Haitham Ahmed, Khaled Ahmed, Refaat Ahmed

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

The method for assessing the bowel length is debatable but crucial in bariatric surgeries, especially revisional ones. It may be linked to improved weight loss and reducing nutritional deficiencies; however, it can be time-consuming, increasing the likelihood of complications during and after the surgery. 3D CT volumetry could offer a non-invasive, time-saving alternative for accurate Total Bowel Length (TBL) measurement, potentially reducing operative time and associated risks.

OBJECTIVE

This study compares small bowel length using 3D CT volumetry versus in vivo laparoscopic measurement with pre-marked graspers, and assesses the time consumed intra-operatively for TBL measurement in cases of revisional bariatric surgery.

METHODS

This cross-sectional study included 34 bariatric surgery candidates undergoing revisional or conversion bariatric surgery requiring bowel length estimation. Surgeries included Roux-en-Y gastric bypass (RYGB), single anastomosis duodeno-ileal bypass with sleeve gastrectomy (SADI-S), one-anastomosis gastric bypass (OAGB), banded Roux-en-Y gastric bypass (banded RYGB), and distalization. Pre-operatively, 3D CT volumetry-based bowel length measurements were performed and interpreted by the same radiologist, and compared with intraoperative bowel measurements, which were estimated in vivo laparoscopically using pre-marked graspers. A single surgeon did all the surgical procedures.

RESULTS

The participants had an average age of 42.0 years and a mean BMI of 40.4 ± 7.6 kg/m². The cohort was predominantly female (73.5%). The bowel length estimation took an average of 19 ± 4 min intra-operatively. A comparison of radiographic and intraoperative measurements showed no significant differences for TBL (P = 0.264). The intraclass correlation (ICC) for radiographic and intraoperative measurements showed that radiographic TBL shows acceptable consistency (P = 0.007).

CONCLUSION

3D CT volumetry can be considered a reliable and safe method for TBL assessment. It aids in accurate preoperative planning, reduces operative time, and avoids the risks encountered during intraoperative bowel measurements in bariatric surgery.

KEY POINTS: • An ideal bowel length should achieve effective weight loss while minimizing nutritional deficiencies. • Estimation of total bowel length using 3D CT volumetry shows reliable results compared to intraoperative measurements. • Estimation of total bowel length using 3D CT volumetry minimizes operative time.

Для цитирования: Abdelsalam Ahmed, Ghobashy Ahmed, Abdellatif Ahmed, Elholiby Tamer, Haitham Ahmed, Khaled Ahmed, Refaat Ahmed. Small Intestine Length Measurement Using 3D CT Volumetry and in Vivo Laparoscopic Measurement Using Pre-marked Graspers: A Comparative Study.. Obesity surgery. 2026. DOI: 10.1007/s11695-025-08446-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.