DOI 10.1002/mp.17698

Медицинская библиотека · Medical physics · 2025

Enhancing accuracy in proton therapy: The impact of geometric uncertainty models in head and neck cancer treatment.

Zhang Ying, Chan Mark Ka Heng

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Anatomical changes present a major source of uncertainty in head and neck (H&N) cancer treatment. Accurate modeling of these changes is important for enhancing treatment precision and supporting better outcomes.

PURPOSE: The purpose of this study is to assess different anatomical uncertainty modeling methods in robust optimization for H&N cancer proton therapy.

METHODS

This retrospective study involved five nasopharynx radiotherapy patients. We compared conventional robust optimization with anatomical robust optimization (aRO): (1) conventional robust optimization (cRO-3 mm), which used 3 mm setup shift and 3% range uncertainty. (2) aRO_AM which used three predicted images from an AM capturing systematic anatomical changes, with a 1 mm setup shift and 3% range uncertainty. (3) aRO_PM, which used three predicted images from a probability model (PM) capturing the most probable deformations, also with a 1 mm setup shift and 3% range uncertainty. We assessed weekly dose coverage of the clinical target volumes (CTVs). Normal tissue complication probability (NTCP) for grade ≥ $\ge$ 2 xerostomia and grade ≥ $\ge$ 2 dysphagia were calculated using the accumulated nominal dose (without errors).

RESULTS

aRO_PM outperformed cRO-3 mm and aRO_AM, consistently achieving V94 voxmin $_{\text{voxmin}}$ ≥ $\ge$ 95% for all cases across treatment weeks. Additionally, aRO_PM reduced the NTCP for grade ≥ $\ge$ 2 xerostomia by an average of 4.88 %, with a maximum reduction of 8.03%, and reduced the NTCP for grade ≥ $\ge$ 2 dysphagia by an average of 1.80%, with a maximum reduction of 4.23 %.

CONCLUSION

The PM demonstrates potential for improving robust optimization by effectively managing anatomical uncertainties in H&N cancer proton therapy, thereby enhancing treatment effectiveness.

Для цитирования: Zhang Ying, Chan Mark Ka Heng. Enhancing accuracy in proton therapy: The impact of geometric uncertainty models in head and neck cancer treatment.. Medical physics. 2025. DOI: 10.1002/mp.17698.

Предметные рубрики MeSH