DOI 10.1111/j.1440-1746.2009.06113.x

Медицинская библиотека · Journal of gastroenterology and hepatology · 2010

Diagnostic accuracy of multidetector-row computed tomography for hilar cholangiocarcinoma.

Akamatsu Nobuhisa, Sugawara Yasuhiko, Osada Hisato, Okada Takenori, Itoyama Shinji, Komagome Masahiko, Shin Nobuhiro, Cho Narihiro, Ishida Takashi, Ozawa Fumiaki, Hashimoto Daijo

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIM: The aim of this study was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for the evaluation of tumor spread in hilar cholangiocarcinoma.

METHODS

Images obtained from a 16-detector row scanner of 22 patients were interpreted. The diagnostic accuracy of longitudinal ductal spread, vertical invasion (including hepatic parenchyma), and lymph node metastasis was assessed with reference to histopathological findings.

RESULTS

The location of the tumor was correctly diagnosed in 95% of cases (21/22), but in five of these cases, the cut end of the intrahepatic bile duct was positive, resulting in 77% diagnostic accuracy for longitudinal spread. Among the patients with a negative bile duct surgical margin, there was a significant difference in the measurement of tumor spread between MDCT and microscopic investigation (P < 0.001). For vertical invasion, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT were 69%, 100%, 100%, and 69% for the liver parenchyma, respectively. The sensitivity, specificity, PPV, and NPV of MDCT for lymph node metastasis were 50%, 75%, 43%, and 80%, respectively.

CONCLUSIONS

The diagnostic accuracy of MDCT for tumor location and vertical invasion was satisfactory, but ductal spread was underestimated in comparison with microscopic measurements.

Для цитирования: Akamatsu Nobuhisa, Sugawara Yasuhiko, Osada Hisato, Okada Takenori, Itoyama Shinji, Komagome Masahiko, Shin Nobuhiro, Cho Narihiro, Ishida Takashi, Ozawa Fumiaki, Hashimoto Daijo. Diagnostic accuracy of multidetector-row computed tomography for hilar cholangiocarcinoma.. Journal of gastroenterology and hepatology. 2010. DOI: 10.1111/j.1440-1746.2009.06113.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.