Ophthalmology science · 2026

Validation of the Reaction Time-Based False-Positive Rate as a Reliability Index for Standard Automated Perimetry.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nomoto Hiroki, Okuyama Sachiko, Matsumoto Chota, Kimura Tairo, Yoshikawa Keiji, Mizoue Shiro, Nanno Mami, Kimura Shinji, Inoue Satoshi, Kusaka Shunji

Аннотация

PURPOSE: To validate a reaction time (RT)-based false-positive rate (RT-FP) for standard automated perimetry (SAP) and to determine the optimal RT listening window.

DESIGN: Retrospective cross-sectional study.

PARTICIPANTS: A total of 1201 eyes from 607 glaucoma patients tested with the AIZE algorithm (imo perimeter, 24plus[1-2] pattern).

METHODS: Reaction time-based FP rate was defined as the proportion of stimulus responses below a defined RT listening window, excluding catch trials. Listening windows of 100, 200, and 300 ms were compared using receiver operating characteristic (ROC) analysis against conventional catch-trial FP rate ≥15%. The effect of excluding responses at locations with estimated threshold ≤0, ≤5, ≤10, and ≤15 dB on the association between RT-FP and disease severity was evaluated using Spearman correlation with mean deviation (MD). Relative variability of each FP index was assessed using the coefficient of variation (CV).

MAIN OUTCOME MEASURES: Area under the ROC curve (AUC) for discriminating conventional FP ≥15%, Spearman correlation with MD and CV.

RESULTS: A 300-ms listening window achieved the highest discriminative accuracy (AUC = 0.783), outperforming 200-ms (AUC = 0.733) and 100-ms (AUC = 0.718) listening windows (both P < 0.001). Without location exclusion, RT-FP showed association between RT-FP and disease severity (rs = -0.185, P < 0.001). Among the exclusion thresholds evaluated, excluding responses at locations with estimated threshold ≤10 dB most effectively reduced this bias to rs = -0.081 (P < 0.01), equivalent to conventional FP (rs = -0.081, P < 0.01). The optimized RT-FP showed lower relative variability than the conventional FP rate (CV, 1.27 vs. 1.52). Among eyes with conventional FP ≥15%, 37.9% had normal RT-FP and mild disease.

CONCLUSION: Reaction time-based FP rate with a 300-ms listening window restricted to locations with estimated threshold >10 dB substantially reduced metric dependence on disease severity to levels comparable to conventional FP, with greater measurement stability and no requirement for dedicated catch trials. This optimized RT-FP represents a promising reliability index for SAP warranting prospective validation.

FINANCIAL DISCLOSURES: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.