Comparison of Nasopharyngeal Airway with Endoscopic Respiratory Mask for Hypoxemia in Painless Gastrointestinal Endoscopy in Obese Outpatients: Study Protocol for a Randomized Controlled Trial.

Xiang Dongmei, Deng Lei, Zhou Rui, Zhang Xianjie, Tian Lei, Jiang Wencai, Zhou Yukai, Chen Wenya, Peng Yanhua

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Sedatives and anesthetics can modify airway tone and induce respiratory depression, exacerbating the gas exchange impairments associated with obesity. In obese patients undergoing gastrointestinal endoscopy, upper airway obstruction and hypoventilation are prevalent, leading to frequent occurrences of hypoxemia during the procedure. This study aims to investigate the effects of the nasopharyngeal airway in mitigating hypoxemia via alleviating upper airway obstruction in obese outpatients during painless gastrointestinal endoscopy procedure.

METHODS

This is a prospective single-center randomized controlled study. After signing the written informed consent, eligible outpatients scheduled for painless gastrointestinal endoscopy will be randomly allocated into the nasopharyngeal airway group (group N) and control group (group C), with 88 patients in each group. Patients in group N will undergo intubation of the nasopharyngeal airway prior to examination, whereas patients in group C will receive oxygen therapy through an endoscopic respiratory mask at a flow rate of 10 L/min during the procedure. All patients in two groups will receive propofol and opioids for procedural sedation. The primary outcome will be the incidence of hypoxemia. The secondary outcomes will be the incidence of epistaxis, suspended examination due to hypoxemia, manual ventilation, the times of attempt to nasopharynx airway insertion, duration of insertion of nasopharyngeal airway, tracheal/laryngeal mask intubation, adverse cardiovascular events, gastrointestinal complications, VAS score of nasopharynx pain after removing the nasopharyngeal airway, satisfaction score of patients, endoscopist and anesthesiologists.

DISCUSSION: This study evaluates the effects of nasopharyngeal airway insertion on hypoxemia caused by procedural sedation in obese patients undergoing gastrointestinal endoscopy. The results of this study are expected to provide evidence for the use of nasopharyngeal airway in obese outpatients.

TRIAL REGISTRATION NUMBER: ChiCTR2300078892.

Для цитирования: Xiang Dongmei, Deng Lei, Zhou Rui, Zhang Xianjie, Tian Lei, Jiang Wencai, Zhou Yukai, Chen Wenya, Peng Yanhua. Comparison of Nasopharyngeal Airway with Endoscopic Respiratory Mask for Hypoxemia in Painless Gastrointestinal Endoscopy in Obese Outpatients: Study Protocol for a Randomized Controlled Trial.. Medical devices (Auckland, N.Z.). 2025. DOI: 10.2147/mder.s499308.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.