MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.cn112138-20200413-00367

Медицинская библиотека · Zhonghua nei ke za zhi · 2020

[Diagnostic value of 4-dimensional computed tomography in preoperative localization in patients with primary hyperparathyroidism].

Song A, Wang O, Liu C X, Wang M, Liu H, Jing H L, Hu Y, Xia W B, Zhang Z H, Jin Z Y, Xing X P

СтатьяПеревод в очереди

Аннотация

Objective

To provide more options for preoperative localization diagnosis in patients with primary hyperparathyroidism (PHPT), the diagnostic efficacy of parathyroid 4-dimensional computed tomography (4D-CT) in patients with PHPT was evaluated.

Methods

This was a single-center retrospective study including 57 patients with surgical proved PHPT. All of the patients underwent 4D-CT, 99Tcm -sestamibi parathyroid imaging (MIBI), and ultrasonography (US) preoperatively. The reference standard for correct localization was based on operation reports and pathology confirmation. The patients were grouped according to the preoperative serum calcium levels, tumor diameter, or ectopic lesions (yes/no), respectively. The sensitivity, specificity, positive predictive value, negative predictive value and area under the curve (AUC) of 4D-CT, MIBI and US, alone or in combination, were analyzed in total and each subgroup patients.

Results

Fifty-seven patients (39 women, 18 men; mean age of 56.5 years) were evaluated, including four cases with multi-gland disease and thirteen cases with ectopic parathyroid lesions. In all the patients, similar diagnostic efficacy was found in 4D-CT (AUC: 0.943) and MIBI (AUC: 0.927), both of which were higher than that of US (AUC: 0.847) (P = 0.01 for 4D-CT vs. US; P = 0.04 for MIBI vs. US). In a subset analysis for ectopic quadrants, the diagnostic efficacy of 4D-CT was significantly higher than that of MIBI (P = 0.04) or US (P = 0.01), with the sensitivity of 100%, 69.2%, and 61.5%, and AUC of 0.989, 0.846, and 0.808 for 4D-CT, MIBI and US, respectively.

Conclusions

4D-CT has similar diagnostic efficacy for preoperative localization to MIBI in patients with PHPT, and it is superior to MIBI and US in identifying the ectopic parathyroid gland. 4D-CT can be recommended as an alternative preoperative localization method, especially when parathyroid lesions could not be precisely located by US and MIBI.

Для цитирования: Song A, Wang O, Liu C X, Wang M, Liu H, Jing H L, Hu Y, Xia W B, Zhang Z H, Jin Z Y, Xing X P. [Diagnostic value of 4-dimensional computed tomography in preoperative localization in patients with primary hyperparathyroidism].. Zhonghua nei ke za zhi. 2020. DOI: 10.3760/cma.j.cn112138-20200413-00367.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.